Cadmium (Cd) has toxic effect in human body and exists as the inorganic (Cd) and organic (R-Cd) forms in human biological matrix. Due to cadmium toxicity in various forms, the speciation of cadmium in human blood samples is very important. In this study, the FeO-supported naphthalene-1-thiol- functionalized graphene oxide (FeO@NpSH-GO, NMNT-GO) as a novel nanomagnetic composite was used for cadmium speciation in blood samples by ultrasound-assisted dispersive magnetic micro solid phase extraction (USA-DM-μ-SPE). By procedure, 20 mg of the NMNT-GO was used for extraction of Cd(II) from 1 mL of human blood samples at pH = 6.0, before determined by electrothermal atomic absorption spectrometry (ET-AAS). The total cadmium (T-Cd) was obtained by converting organic (R-Cd) to inorganic form (Cd), before adjusting pH and continuing with USA-DM- μ-SPE procedure. The organic cadmium was simply calculated by subtracting total cadmium from inorganic cadmium content. In optimized conditions, the linear range (peak area), limit of detection (LOD) and the preconcentration factor were obtained 30-1520 ng L, 10 ng L and 4.88 in human blood samples, respectively (RSD: 1.1 %). The adsorption capacities of the FeO@NpSH-GO and the GO were achieved 185.3 mg g and 33.7 mg g for inorganic cadmium, respectively. The results were validated by certified reference materials (CRM, NIST) and inductively coupled plasma mass spectrometry (ICP-MS) in human blood samples.
镉(Cd)在人体中有毒性作用,以无机(Cd)和有机(R-Cd)形式存在于人体生物基质中。由于各种形式的镉毒性,血液样品中镉的形态非常重要。在这项研究中,使用负载 FeO 的萘-1-硫醇功能化氧化石墨烯(FeO@NpSH-GO,NMNT-GO)作为一种新型纳米磁性复合材料,通过超声辅助分散磁固相萃取(USA-DM-μ-SPE)对血液样品中的镉进行形态分析。通过程序,在 pH = 6.0 下,从 1 毫升人血样中用 20 mg 的 NMNT-GO 提取 Cd(II),然后用电感耦合等离子体质谱法(ET-AAS)测定。总镉(T-Cd)通过将有机(R-Cd)转化为无机形式(Cd)获得,然后调整 pH 值并继续进行 USA-DM-μ-SPE 程序。通过从无机镉含量中减去总镉,可以简单地计算出有机镉的含量。在优化条件下,在人血样中得到 30-1520 ng L、10 ng L 和 4.88 的线性范围(峰面积)、检测限(LOD)和预浓缩因子(RSD:1.1%)。FeO@NpSH-GO 和 GO 的吸附容量分别为 185.3 和 33.7 mg g,用于无机镉。在人血样中,通过认证参考材料(CRM,NIST)和电感耦合等离子体质谱法(ICP-MS)验证了结果。