Suppr超能文献

一卢比超灵敏可穿戴柔性低压传感器。

One-Rupee Ultrasensitive Wearable Flexible Low-Pressure Sensor.

作者信息

Kumar Ashok

机构信息

CSIR-National Physical Laboratory, Dr. K.S. Krishnan Marg, New Delhi 110012, India.

Academy of Scientific and Innovative Research (AcSIR), CSIR-National Physical Laboratory (CSIR-NPL) Campus, Dr. K.S. Krishnan Marg, New Delhi 110012, India.

出版信息

ACS Omega. 2020 Jun 29;5(27):16944-16950. doi: 10.1021/acsomega.0c02278. eCollection 2020 Jul 14.

Abstract

A capacitive flexible pressure sensor with polydimethylsiloxane (PDMS) as an elastomeric dielectric layer sandwiched between two flexible conducting electrodes is developed. The porosity/flexibility of PDMS has been increased by altering its microstructure by incorporating a thin layer of a scrubber into the dielectric layer to improve the pressure sensitivity. The fabricated sensor with a porous PDMS-scrubber composite (microstructured/porous PDMS layer) shows 0.058-25.84% relative capacitance change with varying static pressure from 4.4 Pa to 216 kPa. The sensor device with a porous PDMS layer showed a significantly high sensitivity (%) of 0.0083 Pa in a low-pressure range (less than 0.022 kPa) and has a fast response, long-life, and ultralow pressure detection limit. The sensitivity associated with the device was found to vary with the effective area of the device. The pressure sensitivity associated with devices having an effective area of 324 mm was 10 times more than that of the sensor having an effective area of 36 mm. Due to the high sensitivity of the sensor in a wide pressure range, low manufacturing cost, and simple and convenient way of fabrication, this flexible pressure sensor shows potential for pressure and wearable applications.

摘要

开发了一种电容式柔性压力传感器,其以聚二甲基硅氧烷(PDMS)作为弹性介电层夹在两个柔性导电电极之间。通过在介电层中掺入一层薄的洗涤器来改变其微观结构,从而提高了PDMS的孔隙率/柔韧性,以改善压力敏感性。所制备的具有多孔PDMS-洗涤器复合材料(微结构化/多孔PDMS层)的传感器在4.4 Pa至216 kPa的静态压力变化下显示出0.058 - 25.84%的相对电容变化。具有多孔PDMS层的传感器装置在低压范围(小于0.022 kPa)内显示出0.0083 Pa的显著高灵敏度(%),并且具有快速响应、长寿命和超低压检测极限。发现与该装置相关的灵敏度随装置的有效面积而变化。有效面积为324 mm的装置的压力灵敏度是有效面积为36 mm的传感器的10倍。由于该传感器在宽压力范围内具有高灵敏度、低制造成本以及简单方便的制造方式,这种柔性压力传感器在压力和可穿戴应用方面显示出潜力。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/edff/7364849/1dc8c4ee1386/ao0c02278_0001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验