Mohammed Yasser T, Al-Zaka Iman M
Department of Conservative Dentistry, Ministry of Health, Baghdad, Iraq, Phone: +9647705486540, e-mail:
Department of Conservative Dentistry, College of Dentistry, Mustansiriyah University, Baghdad, Iraq.
J Contemp Dent Pract. 2020 May 1;21(5):490-493.
The aim of this study is to compare the effect of different root canal sealers on the fracture resistance of endodontically treated teeth using AH Plus, GuttaFlow 2, MTA-Fillapex, and TotalFill® BC™ sealers.
Sixty single-rooted mandibular premolar teeth were used in the study. After the decoronation of the crowns of the teeth, we got a 13 mm root length. All samples instrumented using ProTaper Next system reaching file size ×4 as the final master apical file. Gutta-percha (GP) with single cone as obturation technique was carried out to all experimental teeth. Then, the teeth were divided into five groups ( = 12) based on the type of sealer to be used. Group I: AH Plus sealer + GP, Group II: GuttaFlow 2 sealer + GP, Group III: MTA-Fillapex sealer + GP, Group IV: TotalFill BC sealer + GP, and Group V: control (instrumented but unobturated teeth). Embedding all teeth in acrylic resin blocks was carried out and fracture force was measured using a universal testing machine (Instron Corp., Canton, MA, USA) by using metal-like spreader tip on 0.5 mm/m speed. Then, the data were statistically evaluated using one-way analysis of variance (ANOVA) and test (Tukey's test).
Group IV showed higher resistance to fracture than other groups significantly. There was a nonsignificant difference in fracture force between Group I, Group II, and Group III. Group V showed the least fracture resistance than other groups.
Based on this study, TotalFill bioceramic-based sealer was more effective when compared with other sealers and the unobturated group showed the lowest mean fracture resistance.
The use of bioceramic sealer with BC cones enhanced the fracture resistance of endodontically treated teeth.
本研究旨在比较使用AH Plus、GuttaFlow 2、MTA - Fillapex和TotalFill® BC™封闭剂对根管治疗后牙齿抗折性的影响。
本研究使用了60颗单根下颌前磨牙。在去除牙冠后,牙根长度为13毫米。所有样本均使用ProTaper Next系统进行预备,最终主尖锉达到×4号锉。所有实验牙齿均采用单锥牙胶尖充填技术进行充填。然后,根据所用封闭剂的类型将牙齿分为五组(每组n = 12)。第一组:AH Plus封闭剂 + 牙胶尖,第二组:GuttaFlow 2封闭剂 + 牙胶尖,第三组:MTA - Fillapex封闭剂 + 牙胶尖,第四组:TotalFill BC封闭剂 + 牙胶尖,第五组:对照组(仅预备但未充填的牙齿)。将所有牙齿嵌入丙烯酸树脂块中,并使用万能试验机(美国马萨诸塞州坎顿市的Instron公司),以0.5毫米/分钟的速度使用金属类撑开器尖端测量抗折力。然后,使用单因素方差分析(ANOVA)和检验(Tukey检验)对数据进行统计学评估。
第四组显示出比其他组显著更高的抗折性。第一组、第二组和第三组之间的抗折力差异不显著。第五组显示出比其他组最低的抗折性。
基于本研究,与其他封闭剂相比,TotalFill生物陶瓷基封闭剂更有效,且未充填组显示出最低的平均抗折性。
使用含BC锥的生物陶瓷封闭剂可增强根管治疗后牙齿的抗折性。