Suppr超能文献

种植体数量和附着类型对无腭板种植体支持覆盖义齿种植体周围应力及固位的影响

Impact of implants number and attachment type on the peri-implant stresses and retention of palateless implant-retained overdenture.

作者信息

Hegazy Salah A, El Mekawy Nesreen, Emera Radwa M K

机构信息

Department of Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt.

出版信息

Indian J Dent Res. 2020 May-Jun;31(3):414-419. doi: 10.4103/ijdr.IJDR_772_18.

Abstract

OBJECTIVES

To evaluate the impact of implants number and attachments type on the peri-implant stresses and retention of maxillary palateless implant-supported overdenture.

MATERIALS AND METHODS

Four edentulous maxillary educational acrylic resin models were used. According to the implants number and type of attachment used, four groups were compared: Group I, 2-locator attachments in the canine area; Group II, 2- OT equator attachments in the canine area; Group III, 4-locator attachments in the canine, second premolar area and Group IV, 4-OT equator attachments in the canine, second premolar area. Implants retained palateless overdenture was constructed on each model. Four self-protected linear strain gauges were cemented on each implant. A digital loading device was used to apply compressive loads to measure the resulting peri-implant stresses. Forcemeter and Universal testing machines were used to test the retention of palateless overdenture.

RESULTS

A significant difference between the same implant number and distribution with different attachments was found (P = 0.003, P = 0.020), respectively. Least stresses amount was found around the 4-implant locator palateless overdenture, while the highest was found around the 2-implant OT equator palateless overdenture. Nevertheless; the result was that 2-implant locator palateless overdenture recorded insignificant higher retentive forces than the 4-implant OT equator one.

CONCLUSIONS

It can be concluded that the implant-retained palateless overdenture with four locator attachments is considered a promising treatment option regarding stress distribution. Using locator attachments, for implant-retained palateless overdenture with either two or four implants considering their superior retentive properties, is advantageous when compared to OT equator attachments.

摘要

目的

评估种植体数量和附着类型对上颌无腭托种植体支持覆盖义齿种植体周围应力及固位力的影响。

材料与方法

使用四个上颌无牙颌的教学用丙烯酸树脂模型。根据种植体数量和所使用的附着类型,比较四组:第一组,在尖牙区使用2个定位器附着;第二组,在尖牙区使用2个OT赤道附着;第三组,在尖牙、第二前磨牙区使用4个定位器附着;第四组,在尖牙、第二前磨牙区使用4个OT赤道附着。在每个模型上制作种植体固位的无腭托覆盖义齿。在每个种植体上粘结四个自保护线性应变片。使用数字加载装置施加压缩载荷以测量种植体周围产生的应力。使用测力计和万能试验机测试无腭托覆盖义齿的固位力。

结果

发现在相同种植体数量和分布但使用不同附着的情况下存在显著差异(P = 0.003,P = 0.020)。在4种植体定位器无腭托覆盖义齿周围发现的应力最小,而在2种植体OT赤道无腭托覆盖义齿周围发现的应力最大。然而,结果是2种植体定位器无腭托覆盖义齿记录的固位力显著高于4种植体OT赤道无腭托覆盖义齿。

结论

可以得出结论,就应力分布而言,带有四个定位器附着的种植体固位无腭托覆盖义齿被认为是一种有前景的治疗选择。考虑到定位器附着具有优越的固位性能,对于使用两个或四个种植体的种植体固位无腭托覆盖义齿而言,与OT赤道附着相比具有优势。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验