Valizadeh Maryam, Sohrabi Mahmoud Reza, Motiee Fereshte
Department of Chemistry, North Tehran Branch, Islamic Azad University, Tehran, Iran.
Department of Chemistry, North Tehran Branch, Islamic Azad University, Tehran, Iran.
Spectrochim Acta A Mol Biomol Spectrosc. 2020 Dec 5;242:118777. doi: 10.1016/j.saa.2020.118777. Epub 2020 Aug 3.
In this study, a fast, low-cost, accurate, and precise spectrophotometric method based on the continuous wavelet transform (CWT) was assayed to determine dorzolamide (DOR) and timolol (TIM) in an eye drop sample simultaneously. Different wavelet families were investigated to select the best family for analyzing the DOR and TIM. The Mexican hat wavelet (MHW) family with the wavelength of 281 nm and Gaussian wavelet family (gaus2) in the wavelength of 267 nm were found for the simultaneous analysis of DOR and TIM, respectively. Mean recovery values of synthetic mixtures were found 97.44%±2.63 and 99.18%±4.00 for DOR and TIM, respectively. The root mean square errors (RMSE) of DOR and TIM were achieved 0.5550 and 0.3306, respectively. Eye drop as a real sample was analyzed by spectrophotometry coupled with the CWT technique, as well as high-performance liquid chromatography (HPLC) as a reference method. The obtained results were compared with each other by the one-way analysis of variance (ANOVA) test and there was no significant difference between them.
在本研究中,测定了一种基于连续小波变换(CWT)的快速、低成本、准确且精密的分光光度法,用于同时测定滴眼液样品中的多佐胺(DOR)和噻吗洛尔(TIM)。研究了不同的小波族,以选择用于分析DOR和TIM的最佳小波族。分别发现波长为281 nm的墨西哥帽小波(MHW)族和波长为267 nm的高斯小波族(gaus2)可用于同时分析DOR和TIM。合成混合物中DOR和TIM的平均回收率分别为97.44%±2.63和99.18%±4.00。DOR和TIM的均方根误差(RMSE)分别为0.5550和0.3306。采用分光光度法结合CWT技术以及作为参考方法的高效液相色谱法(HPLC)对实际样品滴眼液进行了分析。通过单因素方差分析(ANOVA)检验对所得结果进行了相互比较,结果之间无显著差异。