Medical School of Chinese PLA, Beijing, China.
Department of Otolaryngology-Head and Neck Surgery, Chinese PLA General Hospital, Beijing, China.
Acta Otolaryngol. 2020 Dec;140(12):990-994. doi: 10.1080/00016489.2020.1804074. Epub 2020 Aug 17.
Hearing results of endoscopic and microscopic tympanoplasty have been compared using the average pure tone threshold which could conceal subtle differences at a specific frequency.
To compare frequency-specific hearing outcomes of endoscopic and microscopic tympanoplasty.
The study included 42 patients who underwent endoscopic or microscopic type I tympanoplasty. The medical charts of these patients were reviewed retrospectively. We evaluated the pure tone audiometry at 250, 500, 1000, 2000 and 4000 Hz, including bone conduction (BC), air conduction (AC) and air-bone gap (ABG) before and after the surgery. The main outcome measures were frequency-specific pre- and post-operative hearing thresholds and the corresponding changes. We also assessed the graft success rate and surgical complications.
BC revealed a significant aggravation at 4000 Hz in microscopic tympanoplasty group, but no significant differences between the two groups at any frequencies. Both groups showed improvements in AC and ABG at all frequencies, without significant differences between the two groups at any single frequency. The maximum improvement of AC and ABG was found at 250 Hz. The graft success rate and operative complications were also similar.
The frequency-specific hearing outcomes of endoscopic and microscopic tympanoplasty are similar.
使用平均纯音阈值比较了内镜和显微镜鼓室成形术的听力结果,而该阈值可能掩盖了特定频率下的细微差异。
比较内镜和显微镜鼓室成形术的频率特异性听力结果。
本研究纳入了 42 例接受内镜或显微镜 I 型鼓室成形术的患者。回顾性分析这些患者的病历。我们评估了术前和术后 250、500、1000、2000 和 4000 Hz 的纯音测听,包括骨导(BC)、气导(AC)和气骨导差(ABG)。主要观察指标为术前和术后的频率特异性听力阈值及其相应变化。我们还评估了移植物成功率和手术并发症。
显微镜鼓室成形组在 4000 Hz 时 BC 明显恶化,但两组在任何频率均无显著差异。两组在所有频率的 AC 和 ABG 均有改善,且在任何单一频率均无显著差异。AC 和 ABG 的最大改善出现在 250 Hz。移植物成功率和手术并发症也相似。
内镜和显微镜鼓室成形术的频率特异性听力结果相似。