Abstract

STATEMENT OF PROBLEM

Studies on the intaglio surface trueness and margin quality of interim crowns fabricated using stereolithography apparatus (SLA) 3D printing depending on the type of tooth and the build angle are lacking.

PURPOSE

The purpose of this in vitro study was to evaluate the effects of intaglio surface trueness and margin quality in accordance with the type of tooth and the build angles of interim crowns fabricated by SLA 3D printing.

MATERIAL AND METHODS

A definitive cast was digitized for computer-aided design (CAD) reference model (CRM) production, and the interim crown was designed by using a CAD software program and saved as a standard tessellation language (STL) file. For CAD test model (CTM) production, 3D printing was performed in accordance with the type of tooth (maxillary central incisor, first premolar, and first molar) and the build angles (90, 120, 135, 150, 180, 210, 225, 240, and 270 degrees) (n=17). The intaglio surface of the printed interim crown was digitized. CRM and CTM used 3D inspection software to analyze the intaglio surface superimposition and root mean square (RMS). In addition, a grading system was developed to evaluate the margin quality, which was assessed visually. Statistical analysis was performed using 1-way ANOVA, 2-way ANOVA, and the Tukey honestly significant difference post hoc test (α=.05).

RESULTS

The RMS value showed significant differences in the various types of tooth as per the build angles (P<.001). The central incisor and first premolar showed the lowest RMS value at 180 degrees, and the first molar showed the lowest RMS value at 210 degrees. The margin quality was significantly different as per the build angle in the central incisor and the first molar (P<.05). The worst margin quality observed in all teeth was at 180 degrees.

CONCLUSIONS

In 3D printing, the build angle affected the intaglio surface trueness of the interim crown. The recommended build angle for interim crowns fabricated using 3D printing is between 150 and 210 degrees. The tooth type affected the margin quality according to the build angle, except in the case of first premolars.

摘要

问题陈述

关于使用立体光固化成型(SLA)3D 打印制作的临时冠的凹面精度和边缘质量,针对不同牙齿类型和构建角度的研究尚缺乏。

目的

本体外研究的目的是评估根据 SLA 3D 打印制作的临时冠的牙齿类型和构建角度对凹面精度和边缘质量的影响。

材料和方法

对恒牙进行数字化以制作计算机辅助设计(CAD)参考模型(CRM),并使用 CAD 软件程序设计临时冠,然后将其保存为标准 tessellation language(STL)文件。为制作 CAD 测试模型(CTM),根据牙齿类型(上颌中切牙、第一前磨牙和第一磨牙)和构建角度(90、120、135、150、180、210、225、240 和 270 度)(n=17)进行 3D 打印。打印的临时冠的凹面进行数字化。CRM 和 CTM 使用 3D 检测软件分析凹面叠加和均方根(RMS)。此外,还开发了一种分级系统来评估边缘质量,并进行视觉评估。使用单向方差分析、双向方差分析和 Tukey Honestly Significant Difference 事后检验(α=.05)进行统计分析。

结果

根据构建角度,各种类型牙齿的 RMS 值存在显著差异(P<.001)。中切牙和第一前磨牙在 180 度时 RMS 值最低,第一磨牙在 210 度时 RMS 值最低。中切牙和第一磨牙的边缘质量根据构建角度存在显著差异(P<.05)。所有牙齿中,边缘质量最差的是在 180 度。

结论

在 3D 打印中,构建角度会影响临时冠的凹面精度。推荐用于 3D 打印制作临时冠的构建角度在 150 度至 210 度之间。牙齿类型会根据构建角度影响边缘质量,但第一前磨牙除外。