Dwivedi Aparna, Maru Kavita, Sharma Aakash
Department of Prosthodontics and Crown & Bridge, College of Dental Sciences and Hospital, Rau, Indore, India.
Department of Prosthodontics and Crown & Bridge, Sri Aurobindo College of Dentistry, Indore, India.
Med Pharm Rep. 2020 Jul;93(3):280-286. doi: 10.15386/mpr-1453. Epub 2020 Jul 22.
The interocclusal registration materials record the occlusal relationship between the natural and /or artificial teeth for planning an occlusal rehabilitation in removable and fixed partial dentures.
The aim of this in vitro study was to evaluate and compare the accuracy and the three dimensional stability offered by three different types of interocclusal recording materials at storage time intervals of 1 hour and 24 hours.
Three commercially available interocclusal recording materials were used: Group I-Polyether bite registration paste (Ramitec), Group II-Polyvinylsiloxane bite registration material (Imprint), Group III-Bite registration wax (Maarc). The test was carried out using an epoxy resin model. A total of 30 samples were made with each group consisting of ten samples. Three dimensional measurements were carried out by using 3D-Coordinate measuring machine (CMM) at time intervals of 0-1 hour and 0-24 hours in X, Y and Z-axis.
Twelve readings were obtained for three axes (4 readings for each sample at 1 axis) and the averages of these four values were noted for a particular axis (X/Y/Z). Statistical analysis was performed using analysis of variance (ANOVA) for comparison among the groups and then Tukey's honestly significant difference (HSD) tests was performed for comparison among groups at the 0.05 level of significance.
Polyvinylsiloxane was dimensionally the most stable material followed by polyether and finally bite registration wax. Dimensional accuracy and stability is influenced by both "material" and "time" factors.
牙合间记录材料记录天然牙和/或人工牙之间的牙合关系,用于可摘局部义齿和固定局部义齿的牙合重建计划。
本体外研究的目的是评估和比较三种不同类型的牙合间记录材料在1小时和24小时储存时间间隔下的准确性和三维稳定性。
使用三种市售的牙合间记录材料:第一组-聚醚咬合记录糊剂(Ramitec),第二组-聚乙烯基硅氧烷咬合记录材料(Imprint),第三组-咬合记录蜡(Maarc)。试验使用环氧树脂模型进行。每组共制作30个样本,每组由10个样本组成。在0-1小时和0-24小时的时间间隔内,使用三维坐标测量机(CMM)在X、Y和Z轴上进行三维测量。
在三个轴上获得了12个读数(每个样本在一个轴上有4个读数),并记录了特定轴(X/Y/Z)上这四个值的平均值。使用方差分析(ANOVA)进行统计分析以比较各组之间的差异,然后在0.05显著性水平下进行Tukey's真实显著性差异(HSD)检验以比较各组之间的差异。
聚乙烯基硅氧烷在尺寸上是最稳定的材料,其次是聚醚,最后是咬合记录蜡。尺寸精度和稳定性受“材料”和“时间”因素的影响。