Suppr超能文献

99mTc-DTPA的肺清除:本底活性的影响

Pulmonary clearance of 99mTc-DTPA: influence of background activity.

作者信息

Barrowcliffe M P, Otto C, Jones J G

机构信息

Department of Anesthesiology, University of Arizona Health Sciences Center, Tucson 85721.

出版信息

J Appl Physiol (1985). 1988 Mar;64(3):1045-9. doi: 10.1152/jappl.1988.64.3.1045.

Abstract

We examined the effect of intravascular and tissue accumulation of tracer when measuring pulmonary clearance of sodium pertechnetate-labeled diethylenetriamine pentaacetate (99mTc-DTPA). Pigs were intubated with endobronchial tubes, permitting deposition of an aerosol of 99mTc-DTPA only into the left lung. Scintillation detectors recorded radioactivity separately from one thigh and from the lung and chest wall on the left and right side. 99mTc-DTPA was given intravenously after 30 min, so that the chest counts from the left lung could be corrected for background activity in either the right lung or the thigh. The uncorrected clearance half time (t1/2) mean +/- SE from the left chest was 118.5 +/- 14.4 min. When corrected for background activity in the right chest, the t1/2 was 82.1 +/- 10.5 min, and when corrected for background activity in the thigh, the t1/2 was 80.9 +/- 10.6 min. There was no significant difference between t1/2 corrected by the measurements from the right chest or the thigh, and in four of five animals the corrected t1/2 by either method was significantly different from the uncorrected t1/2 (P less than 0.05). There was no correlation between the uncorrected t1/2 and the magnitude of the required correction. We conclude that correction for intravascular and tissue accumulation of tracer is an important refinement of the technique and can easily be accomplished by measuring accumulation of tracer in the thigh.

摘要

在测量高锝酸钠标记的二乙三胺五乙酸(99mTc-DTPA)的肺清除率时,我们研究了示踪剂在血管内和组织中的蓄积效应。给猪插入支气管内导管,使99mTc-DTPA气雾剂仅沉积于左肺。闪烁探测器分别记录一侧大腿以及左右侧肺和胸壁的放射性。30分钟后静脉注射99mTc-DTPA,以便对左肺的胸部计数进行校正,校正依据为右肺或大腿的本底活性。左胸未经校正的清除半衰期(t1/2)均值±标准误为118.5±14.4分钟。以右胸本底活性校正后,t1/2为82.1±10.5分钟;以大腿本底活性校正后,t1/2为80.9±10.6分钟。用右胸测量值校正的t1/2与用大腿测量值校正的t1/2之间无显著差异,并且在五只动物中有四只,两种方法校正后的t1/2与未校正的t1/2均有显著差异(P<0.05)。未校正的t1/2与所需校正量之间无相关性。我们得出结论,校正示踪剂在血管内和组织中的蓄积是该技术的一项重要改进,并且通过测量示踪剂在大腿中的蓄积量即可轻松实现。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验