Kujirai Hitoshi, Itaya Sakiko, Ono Yumi, Takahashi Makoto, Inaba Akira, Shimo Yasushi, Hattori Nobutaka, Orimo Satoshi
Department of Neurology, Kanto Central Hospital, Tokyo 158-8531, Japan.
Department of Neurology, Juntendo University School of Medicine, Tokyo 113-8421, Japan.
Parkinsons Dis. 2020 Aug 10;2020:5892163. doi: 10.1155/2020/5892163. eCollection 2020.
The rotigotine transdermal patch (RTP) is a dopamine agonist used to treat Parkinson's disease (PD). Some PD patients cannot continue RTP treatment due to application site reactions. We explored sites for RTP where application site reactions are less severe than those in the six approved application sites. Thirty PD patients (12 men, mean age = 76 years) who underwent RTP at the approved sites and had some application site reactions were enrolled in this study. When applying the RTP to the approved application sites for more than four weeks (pre-RTP) and then on the shin for the following four weeks (post-RTP), skin reactions, itching evaluated using the skin irritation score, motor symptoms, clinical global impressions scale, and plasma rotigotine concentration were examined. The mean visual analogue scale and skin irritation score in the post-RTP group were significantly lower than those in the pre-RTP group. The mean Movement Disorder Society-Unified Parkinson's Disease Rating Scale part III score in the post-RTP group was slightly but significantly lower than that in the pre-RTP group. Plasma rotigotine concentration in the post-RTP group was slightly but significantly lower than that in the pre-RTP group. These results indicate that the shin can be a useful application site for RTP.
罗替戈汀透皮贴剂(RTP)是一种用于治疗帕金森病(PD)的多巴胺激动剂。一些帕金森病患者由于应用部位反应而无法继续使用RTP治疗。我们探索了RTP的应用部位,这些部位的应用部位反应比六个获批应用部位的反应轻。30名在获批部位接受RTP治疗且有一些应用部位反应的帕金森病患者(12名男性,平均年龄 = 76岁)纳入本研究。在获批应用部位应用RTP超过四周(RTP前),然后在接下来的四周内在小腿应用(RTP后),检查皮肤反应、使用皮肤刺激评分评估的瘙痒、运动症状、临床总体印象量表和血浆罗替戈汀浓度。RTP后组的平均视觉模拟量表评分和皮肤刺激评分显著低于RTP前组。RTP后组的平均运动障碍协会统一帕金森病评定量表第三部分评分略低于但显著低于RTP前组。RTP后组的血浆罗替戈汀浓度略低于但显著低于RTP前组。这些结果表明,小腿可以作为RTP的一个有用的应用部位。