Radiation dose and repeatability of aortic valve measurement by multidetector row computed tomography to assess eligibility for transcatheter aortic valve implantation.

机构信息

Centre for Diagnostic Imaging, 4th Military Hospital, Wrocław, Poland.

Department of Hygiene, Wroclaw Medical University, Poland.

出版信息

Adv Clin Exp Med. 2020 Aug;29(8):983-992. doi: 10.17219/acem/123624.

Abstract

BACKGROUND

Aortic valve stenosis is among the most common valvular defects in developed countries. In the assessment of eligibility for transcatheter aortic valve implantation (TAVI), multidetector row computed tomography (MDCT) is performed to determine the precise dimensions of the aortic valve, the topography of the aortic ostium and the ability to use various arterial access routes.

OBJECTIVES

To evaluate the relationships between the radiation dose and the repeatability of measurements of dimensions of the aortic valve in MDCT performed before TAVI.

MATERIAL AND METHODS

The study involved a group of 60 consecutive patients undergoing MDCT before TAVI. The radiation dose was expressed as computed tomography dose index volume (CTDIvol) and dose length product (DLP). The coefficient of variation (CV) of each measurement was defined as the standard deviation (SD) of the measurements/mean measurement × 100%, based on the measurements performed independently by 2 radiologists.

RESULTS

A statistically significant negative linear correlation was observed between the DLP value of the MDCT before TAVI, and the CV of the measurement of the minimum dimension of the aortic annulus (r = -0.25; p < 0.05). Lower DLP doses of the MDCT before TAVI constitute an independent factor associated with a higher CV for the measurement of the minimum dimension of the aortic annulus.

CONCLUSIONS

It is proposed that tests using lower radiation doses should be followed by an assessment of the degree of repeatability of the aortic valve sizing.

摘要

背景

在发达国家,主动脉瓣狭窄是最常见的瓣膜缺陷之一。在经导管主动脉瓣植入术(TAVI)的适应证评估中,多排螺旋计算机断层扫描(MDCT)用于确定主动脉瓣的精确尺寸、主动脉瓣窦的形态以及使用各种动脉入路的能力。

目的

评估 TAVI 前 MDCT 测量主动脉瓣尺寸的辐射剂量与可重复性之间的关系。

材料和方法

本研究纳入了 60 例连续接受 TAVI 前 MDCT 的患者。辐射剂量表示为计算机断层扫描剂量指数容积(CTDIvol)和剂量长度乘积(DLP)。每个测量值的变异系数(CV)定义为 2 位放射科医生独立进行的测量值的标准差(SD)/平均测量值×100%。

结果

TAVI 前 MDCT 的 DLP 值与主动脉瓣环最小尺寸测量的 CV 之间呈显著负线性相关(r = -0.25;p < 0.05)。TAVI 前 MDCT 的较低 DLP 剂量是与主动脉瓣环最小尺寸测量的 CV 较高相关的独立因素。

结论

建议使用较低辐射剂量的检查后,应评估主动脉瓣尺寸测量的可重复性程度。