Fuentes Omar, Vaiano Patrizio, Del Villar Ignacio, Quero Giuseppe, Corres Jesús, Consales Marco, Matías Ignacio, Cusano Andrea
Opt Lett. 2020 Sep 1;45(17):4738-4741. doi: 10.1364/OL.402177.
The full width at half maximum (FWHM) of lossy mode resonances (LMRs) in the optical spectrum depends on the homogeneity of the thin film deposited. In this Letter, a method for improving the FWHM is applied for an LMR generated by a D-shaped optical fiber in reflection configuration. For this purpose, three samples with different attenuation were deposited with DC sputtering thin films of , and a further controlled immersion of the samples in water was performed. A laser-cleaner method was used to improve the FWHM characteristics of one of the samples from 106 to 53 nm. This improvement can be applied to thin-film-based sensors where there is a problem with the inhomogeneity of the coating thickness. Moreover, with this technique, it was proved that a coated length of just 3-4 mm permits the generation of an LMR, with implications for the miniaturization of the final device.
光谱中损耗模式共振(LMR)的半高全宽(FWHM)取决于所沉积薄膜的均匀性。在本信函中,一种用于改善FWHM的方法被应用于由反射配置的D形光纤产生的LMR。为此,用直流溅射沉积了具有不同衰减的三个样品薄膜,并且对样品进行了进一步的可控水浸。使用激光清洁方法将其中一个样品的FWHM特性从106nm改善到了53nm。这种改进可应用于涂层厚度不均匀存在问题的基于薄膜的传感器。此外,通过该技术证明,仅3 - 4mm的涂层长度就能够产生LMR,这对最终器件的小型化具有重要意义。