The Scientific and Technological Research Council of Turkey, Marmara Research Center, Environment and Cleaner Production Institute, Kocaeli, Turkey.
Department of Environmental Engineering, Yıldız Technical University, Davutpaşa Campus, Istanbul, Turkey.
Water Environ Res. 2021 Mar;93(3):393-408. doi: 10.1002/wer.1433. Epub 2020 Sep 3.
Medical laboratory wastewaters arising from diagnosis and examination units show highly toxic characteristic. Within the scope of the study, removal of the wastewater's toxicity and increasing BOD /COD ratio of the medical laboratory wastewaters through electro-Fenton (EF) process were investigated. In the study, central composite design was applied to optimize the process parameters of EF for COD, BOD , and toxicity unit (TU) removal. Based on ANOVA, H O /COD was found to be significant parameter for COD removal, whereas current, reaction time, and H O /COD were determined to be significant parameters for BOD and TU removal. Optimum conditions (pH value of 3.4, current 3 A, reaction time 33.9 min, and H O /COD of 1.29) were determined, and predicted removals of COD, BOD and TU were found to be 55.1%, 42.5%, and 99.7% and experimental removals were found to be 53.4%, 41.2%, and 99.5%, respectively. TU value of the wastewater decreased from the value of 163-0.815, and BOD /COD value increased from the value of 0.32-0.39. The results of the study indicate that EF process is an effective treatment option for COD, BOD and especially toxicity removal from medical laboratory wastewater. PRACTITIONER POINTS: Electro-Fenton process was applied medical laboratory wastewater with highly toxic characteristic. Response surface methodology approach using central composite design was employed for modeling. 53.4%, 41.2%, and 99.5% of COD, BOD and toxicity removals were achieved under statistically optimized conditions. TU value of the wastewater decreased from the value of 163-0.815. BOD /COD value increased from the value of 0.32-0.39.
医疗实验室废水来自诊断和检查单元,显示出高度毒性特征。在研究范围内,通过电芬顿(EF)过程去除废水的毒性并提高医疗实验室废水的 BOD/COD 比。在该研究中,应用中心复合设计优化 EF 过程参数以去除 COD、BOD 和毒性单位(TU)。基于方差分析,发现 H2O2/COD 是 COD 去除的重要参数,而电流、反应时间和 H2O2/COD 是 BOD 和 TU 去除的重要参数。确定了最佳条件(pH 值为 3.4、电流 3 A、反应时间 33.9 min 和 H2O2/COD 为 1.29),预测的 COD、BOD 和 TU 去除率分别为 55.1%、42.5%和 99.7%,实验去除率分别为 53.4%、41.2%和 99.5%。废水的 TU 值从 163-0.815 降低,BOD/COD 值从 0.32-0.39 增加。研究结果表明,EF 工艺是一种从医疗实验室废水中去除 COD、BOD 特别是毒性的有效处理方法。