• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

查恩利低摩擦人工关节置换术中髋臼的磨损与松动

Wear and loosening of the socket in the Charnley low-friction arthroplasty.

作者信息

Wroblewski B M

机构信息

Centre for Hip Surgery, Wrightington Hospital, North Wigan, Lancashire, England.

出版信息

Orthop Clin North Am. 1988 Jul;19(3):627-30.

PMID:3288938
Abstract

In the Charnley low-friction arthroplasty, wear of the HDP socket and the dimensional changes resulting from it are more important than the tissue response to wear debris. Study of wear and the related mechanical factors is likely to be more rewarding than the search for alternative methods of fixation.

摘要

在Charnley低摩擦关节成形术中,高密度聚乙烯(HDP)髋臼杯的磨损及其导致的尺寸变化比组织对磨损碎屑的反应更为重要。研究磨损及相关力学因素可能比寻找其他固定方法更有意义。

相似文献

1
Wear and loosening of the socket in the Charnley low-friction arthroplasty.查恩利低摩擦人工关节置换术中髋臼的磨损与松动
Orthop Clin North Am. 1988 Jul;19(3):627-30.
2
Risk factors affecting radiological failure of the socket in primary Charnley low friction arthroplasty. A 10- to 20-year followup study.影响初次Charnley低摩擦人工关节置换术中髋臼放射学失败的危险因素。一项10至20年的随访研究。
Clin Orthop Relat Res. 1994 Sep(306):84-96.
3
Charnley low-friction arthroplasty in the young patient.年轻患者的查恩利低摩擦关节成形术。
Clin Orthop Relat Res. 1992 Dec(285):45-7.
4
Effect of activity levels on polyethylene wear in Charnley low-friction arthroplasty.活动水平对Charnley低摩擦人工关节置换术中聚乙烯磨损的影响。
J R Coll Surg Edinb. 1999 Jun;44(3):193-6.
5
Socket wear in Charnley low friction arthroplasty of the hip.
Clin Orthop Relat Res. 1978 Nov-Dec(137):37-47.
6
Migration and wear of long-term successful Charnley total hip replacements.长期成功的Charnley全髋关节置换术的移位与磨损
J Bone Joint Surg Br. 1998 May;80(3):377-81. doi: 10.1302/0301-620x.80b3.8455.
7
Socket wear of Charnley low friction arthroplasty: fifteen year follow-up.查恩利低摩擦人工关节置换术的髋臼磨损:十五年随访
Bull Hosp Jt Dis. 1993;53(4):37-42.
8
Fracture of a Charnley acetabular component from polyethylene wear.因聚乙烯磨损导致的Charnley髋臼组件骨折。
Clin Orthop Relat Res. 1986 Jun(207):94-6.
9
Loosening of the socket in a 35-mm snap-fit prosthesis and the Charnley hip prosthesis. A roentgenographic evaluation of 321 cases operated upon because of osteoarthritis.35毫米卡扣式假体和Charnley髋关节假体中髋臼的松动。对321例因骨关节炎接受手术的病例进行的X线评估。
Clin Orthop Relat Res. 1988 Mar(228):63-8.
10
A 12- to 18-year radiographic follow-up study of Charnley low-friction arthroplasty. The role of the center of rotation.
Clin Orthop Relat Res. 1993 Nov(296):140-7.

引用本文的文献

1
Long-term results of Charnley low friction arthroplasty in patients younger than 40.
Eur J Orthop Surg Traumatol. 1996 Dec;6(4):241-246. doi: 10.1007/BF03380091. Epub 2017 Mar 10.
2
Press-fit cementless acetabular fixation with and without screws.压配式非骨水泥髋臼固定,带或不带螺钉。
Int Orthop. 2014 Jan;38(1):7-12. doi: 10.1007/s00264-013-2075-2. Epub 2013 Aug 28.
3
Failed hip replacements.髋关节置换失败。
BMJ. 1992 Jan 4;304(6818):3-4. doi: 10.1136/bmj.304.6818.3.