Abstract

PURPOSE

To evaluate the shear bond strength (SBS) and color stability (ΔE) of four ceramic veneers (VITA VM 9; VITA VM 13; VITA VMK 95; and IPS e.max Ceram) following repair with three different self-adhesive composite resins (Fusio Liquid Dentin; Constic; and Vertise Flow) and BISCO Intraoral Repair Kit + Filtek Supreme (BC + FS).

MATERIALS AND METHODS

A total of 96 specimens were prepared per ceramic material, and each ceramic group was divided into subgroups according to testing method (32 specimens for color stability analysis and 64 specimens for SBS testing). ΔE and SBS (SBS = non-aged, SBS = thermally aged) values of the repaired specimens were calculated. One specimen from each of the thermally aged groups was investigated under scanning electron microscopy (SEM). Two-way ANOVA was used to analyze the mean ΔE, SBS, and SBS values. The differences between SBS and SBS values were analyzed using independent-samples t test.

RESULTS

The lowest ΔE values were calculated for Constic (P ≤ .05). The SBS values among all groups were lower than the SBS values (P ≤ .05). The lowest SBS values were observed for Vertise Flow (2.3 ± 1.47 MPa) (P ≤ .05) and were below the acceptable limit of 5 MPa.

CONCLUSION

All of the investigated repair materials in combination with the ceramic veneers exhibited ΔE values that were higher than the clinically acceptable limits. Thermal aging negatively affected the SBS values in all groups (P ≤ .05). All tested self-adhesive composite resins, with the exception of Vertise Flow, could be used instead of a repair kit with flowable composite resin, especially in noncooperative patients, for the purpose of repairing chipping fractures for VITA VM 9, VITA VM 13, and VITA VMK 95 (P > .05).

摘要

目的

评估四种陶瓷贴面(VITA VM 9;VITA VM 13;VITA VMK 95;和 IPS e.max Ceram)在使用三种不同的自粘接复合树脂(Fusio Liquid Dentin;Constic;和 Vertise Flow)和 BISCO Intraoral Repair Kit + Filtek Supreme(BC + FS)修复后的剪切粘接强度(SBS)和颜色稳定性(ΔE)。

材料和方法

每种陶瓷材料制备了 96 个样本,每个陶瓷组根据测试方法分为亚组(32 个样本用于颜色稳定性分析,64 个样本用于 SBS 测试)。计算修复样本的 ΔE 和 SBS(SBS=未老化,SBS=热老化)值。对每个热老化组的一个样本进行扫描电子显微镜(SEM)检查。使用双因素方差分析来分析平均 ΔE、SBS 和 SBS 值。使用独立样本 t 检验分析 SBS 和 SBS 值之间的差异。

结果

Constic 的 ΔE 值最低(P≤.05)。所有组的 SBS 值均低于 SBS 值(P≤.05)。Vertise Flow 的 SBS 值最低(2.3±1.47 MPa)(P≤.05),低于 5 MPa 的可接受限值。

结论

所有研究的修复材料与陶瓷贴面结合使用时,ΔE 值均高于临床可接受范围。热老化对所有组的 SBS 值均有负面影响(P≤.05)。除了 Vertise Flow 之外,所有测试的自粘接复合树脂都可以替代可流动复合树脂的修复套件,特别是在非合作患者中,用于修复 VITA VM 9、VITA VM 13 和 VITA VMK 95 的崩裂骨折(P>.05)。