Nano-CT as tool for characterization of dental resin composites.

机构信息

Department of Biomaterials, Institute of Clinical Dentistry, Faculty of Dentistry, University of Oslo, Geitmyrsveien 71, 0317, Oslo, Norway.

Dental Materials Science, Applied Oral Sciences & Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong, SAR, China.

出版信息

Sci Rep. 2020 Sep 23;10(1):15520. doi: 10.1038/s41598-020-72599-y.

Abstract

Technological advances have made it possible to examine dental resin composites using 3D nanometer resolution. This investigation aims to characterize existing dental nano-hybrid and micro-hybrid resin composites through comparing and contrasting nano-computed tomography (nano-CT) with micro-CT and high-resolution SEM images. Eight commercially available and widely used dental resin composites, 2 micro-hybrid and 6 nano-hybrid were researched. Cured samples were examined and characterized using nano-CT (resolution 450 nm) and compared with micro-CT images (resolution 2 µm). Acquired images were reconstructed and image analysis was carried out to determine porosity and pore morphology. A comprehensive comparison of scanning micrograph images unsurprisingly revealed that the nano-CT images displayed greater detail of the ultrastructure of cured dental resin composites. Filler particle diameters and its volumes were lower when measured using nano-CT, porosity being higher where analysed at higher resolution. There were large variations between the examined materials. Fewer voids were found in Tetric EvoCeram and IPS Empress Direct, the smallest pores being found in Universal XTE and Tetric EvoCeram. Nano-CT was successfully used to investigate the morphology of dental resin composites and showed that micro-CT gives a lower porosity and pore size but overestimates filler particle size. There were large discrepancies between the tested composites. Evidence of porosities and pores within a specimen is a critical finding and it might have a detrimental effect on a material's clinical performance.

摘要

技术进步使得使用 3D 纳米分辨率检查牙科树脂复合材料成为可能。本研究旨在通过对比纳米计算机断层扫描(nano-CT)与微计算机断层扫描和高分辨率扫描电子显微镜图像,来表征现有的牙科纳米复合树脂和微复合树脂。研究了 8 种市售的、广泛使用的牙科树脂复合材料,其中 2 种为微混合复合材料,6 种为纳米混合复合材料。对固化样本进行了检查和纳米 CT(分辨率为 450nm)检测,并与微 CT 图像(分辨率为 2μm)进行了比较。获取的图像进行了重建,进行了图像分析以确定孔隙率和孔径形态。扫描显微图像的综合比较显示,纳米 CT 图像显示了固化牙科树脂复合材料超微结构的更高细节。使用纳米 CT 测量时,填料粒径及其体积较低,在更高分辨率下分析时,孔隙率较高。所检查的材料之间存在很大差异。在 Tetric EvoCeram 和 IPS Empress Direct 中发现的空隙较少,在 Universal XTE 和 Tetric EvoCeram 中发现的孔径最小。纳米 CT 成功地用于研究牙科树脂复合材料的形态,表明微 CT 给出的孔隙率和孔径较小,但高估了填料粒径。测试复合材料之间存在很大差异。样本内的孔隙率和孔径的证据是一个关键发现,它可能对材料的临床性能产生不利影响。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/303c/7511412/55391152934b/41598_2020_72599_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验