Peyman G A, Carney M D, Higginbotham E J
Int Ophthalmol. 1987 Jun;10(3):143-7. doi: 10.1007/BF00139339.
We describe a technique for preserving a filtering bleb in glaucoma patients undergoing pars plana lensectomy and vitrectomy. It involves making a conjunctival incision away from the filtering site and injecting the anterior chamber and bleb with (hyaluronic acid) Healon before vitreous surgery is begun.