Department of Medical Physics, Graduate School of Medicine, Tokyo Women's Medical University, 8-1, Kawada-cho, Shinjuku-ku, Tokyo 162-8666, Japan.
Medical Physics Working Group (MPWG) in Japan Clinical Oncology Group - Radiation Therapy Study Group (JCOG-RTSG), Tokyo, Japan.
J Radiat Res. 2020 Nov 16;61(6):999-1008. doi: 10.1093/jrr/rraa089.
The Japan Clinical Oncology Group-Radiation Therapy Study Group (JCOG-RTSG) has initiated several multicenter clinical trials for high-precision radiotherapy, which are presently ongoing. When conducting multi-center clinical trials, a large difference in physical quantities, such as the absolute doses to the target and the organ at risk, as well as the irradiation localization accuracy, affects the treatment outcome. Therefore, the differences in the various physical quantities used in different institutions must be within an acceptable range for conducting multicenter clinical trials, and this must be verified with medical physics consideration. In 2011, Japan's first Medical Physics Working Group (MPWG) in the JCOG-RTSG was established to perform this medical-physics-related verification for multicenter clinical trials. We have developed an auditing method to verify the accuracy of the absolute dose and the irradiation localization. Subsequently, we credentialed the participating institutions in the JCOG multicenter clinical trials that were using stereotactic body radiotherapy (SBRT) for lungs, intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for several disease sites, and proton beam therapy (PT) for the liver. From the verification results, accuracies of the absolute dose and the irradiation localization among the participating institutions of the multicenter clinical trial were assured, and the JCOG clinical trials could be initiated.
日本临床肿瘤学会放疗研究组(JCOG-RTSG)已经启动了几项高精度放疗的多中心临床试验,目前正在进行中。在进行多中心临床试验时,目标和危及器官的绝对剂量以及照射定位精度等物理量的巨大差异会影响治疗效果。因此,不同机构使用的各种物理量的差异必须在可接受的范围内,才能进行多中心临床试验,这必须通过医学物理方面的考虑来验证。2011 年,JCOG-RTSG 成立了日本首个医学物理工作组(MPWG),负责对多中心临床试验进行与医学物理相关的验证。我们已经开发出一种审核方法来验证绝对剂量和照射定位的准确性。随后,我们对使用立体定向体部放疗(SBRT)治疗肺部、调强放疗(IMRT)和容积调强弧形治疗(VMAT)治疗多个疾病部位以及质子束治疗(PT)治疗肝脏的 JCOG 多中心临床试验的参与机构进行了认证。从验证结果来看,多中心临床试验参与机构的绝对剂量和照射定位精度得到了保证,可以启动 JCOG 临床试验。