Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany.
Private Practice, Frankfurt/Main, Germany.
J Clin Periodontol. 2020 Dec;47(12):1485-1495. doi: 10.1111/jcpe.13374. Epub 2020 Oct 20.
To compare non-contrast-enhanced dental magnetic resonance imaging (NCE-dMRI) and cone-beam computed tomography (CBCT) in assessing horizontal and vertical furcation defects in maxillary molars in vivo.
(NCE-dMRI) and CBCT were performed in 23 patients with severe periodontitis. Sixty-five first/second maxillary molars (195 furcation entrances) were analysed by two independent observers on both modalities to assess the horizontal and vertical components of furcation defects. Reliability of defect classification was evaluated using weighted kappa (κ) statistics. Agreement between NCE-dMRI and CBCT was determined by the Bland-Altman analysis. Sensitivity and specificity of NCE-dMRI were calculated using CBCT as the reference.
Inter-radicular bone loss was observed in 94 furcation entrances. Intra- and inter-rater κ-values were ≥0.9 for both NCE-dMRI and CBCT. The Bland-Altman analysis showed mean differences (95% limits of agreement) of 0.12 mm (-0.67 to 0.90) for horizontal and 0.12 mm (-1.27 to 1.50) for vertical measurements. For the detection of furcation defects, sensitivity/specificity of NCE-dMRI was 98%/100% for horizontal and 99%/99% for vertical components. For defect classification, sensitivity values of NCE-dMRI were 88%/89%/100% (horizontal degree I/II/III) and 95%/91%/80% (vertical subclass A/B/C), respectively.
Non-contrast-enhanced dental magnetic resonance imaging demonstrated high reliability and high agreement with CBCT for the assessment of furcation defects in maxillary molars.
比较非增强型口腔磁共振成像(NCE-dMRI)和锥形束计算机断层扫描(CBCT)在评估上颌磨牙水平和垂直分叉缺损中的应用。
对 23 例严重牙周炎患者进行(NCE-dMRI)和 CBCT 检查。对两种模式下的 65 颗上颌第一/二磨牙(195 个分叉入口)进行了 2 位独立观察者的分析,以评估分叉缺损的水平和垂直成分。采用加权 Kappa(κ)统计评估缺陷分类的可靠性。采用 Bland-Altman 分析确定 NCE-dMRI 和 CBCT 之间的一致性。以 CBCT 为参考,计算 NCE-dMRI 的敏感性和特异性。
94 个分叉入口观察到根间骨丢失。NCE-dMRI 和 CBCT 的内-观察者和间-观察者 κ 值均≥0.9。Bland-Altman 分析显示,水平测量的平均差异(95%可信区间)为 0.12mm(-0.67 至 0.90),垂直测量的平均差异为 0.12mm(-1.27 至 1.50)。对于分叉缺损的检测,NCE-dMRI 的敏感性/特异性分别为 98%/100%(水平度 I/II/III)和 99%/99%(垂直亚类 A/B/C)。对于缺损分类,NCE-dMRI 的敏感性值分别为 88%/89%/100%(水平度 I/II/III)和 95%/91%/80%(垂直亚类 A/B/C)。
非增强型口腔磁共振成像在评估上颌磨牙分叉缺损方面具有较高的可靠性和与 CBCT 的高度一致性。