Suppr超能文献

非增强型口腔磁共振成像和锥形束计算机断层扫描评估上颌磨牙分叉缺损水平和垂直向的比较:一项体内可行性研究。

Comparison of non-contrast-enhanced dental magnetic resonance imaging and cone-beam computed tomography in assessing the horizontal and vertical components of furcation defects in maxillary molars: An in vivo feasibility study.

机构信息

Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany.

Private Practice, Frankfurt/Main, Germany.

出版信息

J Clin Periodontol. 2020 Dec;47(12):1485-1495. doi: 10.1111/jcpe.13374. Epub 2020 Oct 20.

Abstract

AIM

To compare non-contrast-enhanced dental magnetic resonance imaging (NCE-dMRI) and cone-beam computed tomography (CBCT) in assessing horizontal and vertical furcation defects in maxillary molars in vivo.

MATERIALS AND METHODS

(NCE-dMRI) and CBCT were performed in 23 patients with severe periodontitis. Sixty-five first/second maxillary molars (195 furcation entrances) were analysed by two independent observers on both modalities to assess the horizontal and vertical components of furcation defects. Reliability of defect classification was evaluated using weighted kappa (κ) statistics. Agreement between NCE-dMRI and CBCT was determined by the Bland-Altman analysis. Sensitivity and specificity of NCE-dMRI were calculated using CBCT as the reference.

RESULTS

Inter-radicular bone loss was observed in 94 furcation entrances. Intra- and inter-rater κ-values were ≥0.9 for both NCE-dMRI and CBCT. The Bland-Altman analysis showed mean differences (95% limits of agreement) of 0.12 mm (-0.67 to 0.90) for horizontal and 0.12 mm (-1.27 to 1.50) for vertical measurements. For the detection of furcation defects, sensitivity/specificity of NCE-dMRI was 98%/100% for horizontal and 99%/99% for vertical components. For defect classification, sensitivity values of NCE-dMRI were 88%/89%/100% (horizontal degree I/II/III) and 95%/91%/80% (vertical subclass A/B/C), respectively.

CONCLUSIONS

Non-contrast-enhanced dental magnetic resonance imaging demonstrated high reliability and high agreement with CBCT for the assessment of furcation defects in maxillary molars.

摘要

目的

比较非增强型口腔磁共振成像(NCE-dMRI)和锥形束计算机断层扫描(CBCT)在评估上颌磨牙水平和垂直分叉缺损中的应用。

材料和方法

对 23 例严重牙周炎患者进行(NCE-dMRI)和 CBCT 检查。对两种模式下的 65 颗上颌第一/二磨牙(195 个分叉入口)进行了 2 位独立观察者的分析,以评估分叉缺损的水平和垂直成分。采用加权 Kappa(κ)统计评估缺陷分类的可靠性。采用 Bland-Altman 分析确定 NCE-dMRI 和 CBCT 之间的一致性。以 CBCT 为参考,计算 NCE-dMRI 的敏感性和特异性。

结果

94 个分叉入口观察到根间骨丢失。NCE-dMRI 和 CBCT 的内-观察者和间-观察者 κ 值均≥0.9。Bland-Altman 分析显示,水平测量的平均差异(95%可信区间)为 0.12mm(-0.67 至 0.90),垂直测量的平均差异为 0.12mm(-1.27 至 1.50)。对于分叉缺损的检测,NCE-dMRI 的敏感性/特异性分别为 98%/100%(水平度 I/II/III)和 99%/99%(垂直亚类 A/B/C)。对于缺损分类,NCE-dMRI 的敏感性值分别为 88%/89%/100%(水平度 I/II/III)和 95%/91%/80%(垂直亚类 A/B/C)。

结论

非增强型口腔磁共振成像在评估上颌磨牙分叉缺损方面具有较高的可靠性和与 CBCT 的高度一致性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验