Suppr超能文献

通气灌注单光子发射断层扫描半自动分析在肺栓塞诊断中的作用 - 它是否具有额外价值?

Semi-automated Analysis of Ventilation-Perfusion Single-Photon Emission Tomography in the Diagnosis of Pulmonary Embolism - Does it add extra value?

机构信息

Universitätsmedizin Rostock, Klinik und Poliklinik für Nuklearmedizin, Rostock, Germany.

Jordanian Royal Medical Services, King Hussein Medical Center, Amman, Jordan.

出版信息

Nuklearmedizin. 2020 Dec;59(6):445-453. doi: 10.1055/a-1253-7951. Epub 2020 Sep 29.

Abstract

AIM

Diagnosis of pulmonary embolism using V/P-SPECT may include the application of advanced image-processing techniques to identify V/P-mismatches. Aim of this study was to evaluate the benefit in clinical decision making in the diagnosis of pulmonary embolism.by whether adding to conventional reading a software that automatically calculates and visualizes the ventilation/perfusion-quotient pixel by pixel.

METHODS

63 consecutive patients with a clinical suspicion of PE who underwent V/P-SPECT were included in this retrospective study. Images were randomly ordered both for standard as well as for software-assisted reading using V/P-quotients. Studies were read independently by 2 experienced and 2 inexperienced raters. Diagnostic performance and observer agreement of all readers and both reading methods were determined.

RESULTS

Expert observers consistently achieved a high diagnostic accuracy both in conventional as well as in software-assisted reporting (sensitivity: 0.94 vs. 0.94, specificity: 0.96 vs. 0.97, LR: 17.32 vs. 28.86, LR stayed constant at 0.06). For inexperienced readers, diagnostic performance improved: sensitivity raised from 0.74 to 0.85 and specificity from 0.86 to 0.95, LR raised from 5.20 to 15.69, LR decreased from 0.31 to 0.16. Inter-rater reliability (Fleiss' κ) improved from 0.63 to 0.86 by using V/P quotient.

CONCLUSION

Benefit from a software-tool that calculates V/P-ratio automatically is only small when used by experienced physicians If inexperienced readers use the software, the diagnostic accuracy increases. Images generated by automated calculation of V/P-mismatches are easy to read and their use might help to standardize and objectify interpretation of V/P-SPECT in the diagnosis of PE.

摘要

目的

使用 V/P-SPECT 诊断肺栓塞可能包括应用先进的图像处理技术来识别 V/P 不匹配。本研究旨在评估通过添加自动计算和逐像素可视化通气/灌注比的软件,是否能为肺栓塞的诊断提供临床决策的益处。

方法

本回顾性研究纳入了 63 例临床怀疑患有 PE 的连续患者,他们接受了 V/P-SPECT 检查。图像随机排列,分别进行标准阅读和使用软件辅助阅读,计算 V/P 比值。研究由 2 名有经验和 2 名无经验的观察者独立阅读。确定了所有观察者和两种阅读方法的诊断性能和观察者间一致性。

结果

专家观察者在常规报告和软件辅助报告中均达到了较高的诊断准确性(敏感性:0.94 对 0.94,特异性:0.96 对 0.97,LR:17.32 对 28.86,LR 保持在 0.06)。对于无经验的观察者,诊断性能得到改善:敏感性从 0.74 提高到 0.85,特异性从 0.86 提高到 0.95,LR 从 5.20 提高到 15.69,LR 从 0.31 降低到 0.16。使用 V/P 比值后,观察者间可靠性(Fleiss'κ)从 0.63 提高到 0.86。

结论

当由有经验的医生使用时,自动计算 V/P 比值的软件工具的益处很小。如果无经验的读者使用该软件,诊断准确性会提高。自动计算 V/P 不匹配产生的图像易于阅读,其使用可能有助于标准化和客观化 V/P-SPECT 在 PE 诊断中的解释。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验