Suppr超能文献

术后骨盆动力学对全髋关节置换术中髋臼杯三维方位的影响具有患者特异性。

The Effect of Postural Pelvic Dynamics on the Three-dimensional Orientation of the Acetabular Cup in THA Is Patient Specific.

机构信息

T. E. Snijders, A. de Gast, Clinical Orthopedic Research Center midden-Nederland, Diakonessenhuis, Zeist, the Netherlands.

T. E. Snijders, T. P. C. Schlösser, R. M. Castelein, H. Weinans, Department of Orthopaedic Surgery, University Medical Center Utrecht, Utrecht, the Netherlands.

出版信息

Clin Orthop Relat Res. 2021 Mar 1;479(3):561-571. doi: 10.1097/CORR.0000000000001489.

Abstract

BACKGROUND

Sagittal pelvic dynamics mainly consist of the pelvis rotating anteriorly or posteriorly while the hips flexes, and this affects the femoroacetabular or THA configuration. Thus far, it is unknown how the acetabular cup of the THA in the individual patient reorients with changing sagittal pelvic dynamics.

QUESTIONS/PURPOSES: The aim of this study was to validate a method that establishes the three-dimensional (3-D) acetabular cup orientation with changing sagittal pelvic dynamics and describe these changes during functional pelvic dynamics.

METHODS

A novel trigonometric mathematical model, which was incorporated into an easy-to-use tool, was tested. The model connected sagittal tilt, transverse version, and coronal inclination of the acetabular cup during sagittal pelvic tilt. Furthermore, the effect of sagittal pelvic tilt on the 3-D reorientation of acetabular cups was simulated for cups with different initial positions. Twelve pelvic CT images of patients who underwent THA were taken and rotated around the hip axis to different degrees of anterior and posterior sagittal pelvic tilt (± 30°) to simulate functional pelvic tilt in various body positions. For each simulated pelvic tilt, the transverse version and coronal inclination of the cup were manually measured and compared with those measured in a mathematical model in which the 3-D cup positions were calculated. Next, this model was applied to different acetabular cup positions to simulate the effect of sagittal pelvic dynamics on the 3-D orientation of the acetabular cup in the coronal and transverse plane. After pelvic tilt was applied, the intraclass correlation coefficients of 108 measured and calculated coronal and transverse cup orientation angles were 0.963 and 0.990, respectively, validating the clinical use of the mathematical model.

RESULTS

The changes in 3-D acetabular cup orientation by functional pelvic tilt differed substantially between cups with different initial positions; the change in transverse version was much more pronounced in cups with low coronal inclination (from 50° to -29°) during functional pelvic tilt than in cups with a normal coronal inclination (from 39° to -11°) or high coronal inclination (from 31° to 2°). However, changes in coronal inclination were more pronounced in acetabular cups with high transverse version.

CONCLUSION

Using a simple algorithm to determine the dynamic 3-D reorientation of the acetabular cup during functional sagittal pelvic tilt, we demonstrated that the 3-D effect of functional pelvic tilt is specific to the initial acetabular cup orientation and thus per THA patient.

CLINICAL RELEVANCE

Future studies concerning THA (in)stability should not only include the initial acetabular cup orientation, but also they need to incorporate the effect of sagittal pelvic dynamics on the individual 3-D acetabular cup orientation. Clinicians can also use the developed tool, www.3d-hip.com, to calculate the acetabular cup's orientation in other instances, such as for patients with spinopelvic imbalance.

摘要

背景

矢状位骨盆动力学主要包括髋关节屈曲时骨盆的前后旋转,这会影响股髋或 THA 的形态。到目前为止,还不知道个体患者的 THA 髋臼杯在改变矢状位骨盆动力学时如何重新定位。

问题/目的:本研究的目的是验证一种方法,该方法建立了髋臼杯在矢状位骨盆动力学改变时的三维(3-D)髋臼杯方向,并描述了在功能性骨盆动力学过程中这些变化。

方法

测试了一种新的三角数学模型,该模型已纳入一个易于使用的工具中。该模型连接了矢状倾斜、髋臼杯的横向版本和冠状倾斜在矢状位骨盆倾斜时。此外,模拟了不同初始位置的髋臼杯在矢状位骨盆倾斜对髋臼杯 3-D 重新定向的影响。对 12 例接受 THA 的患者进行骨盆 CT 扫描,围绕髋关节轴旋转至前、后矢状位骨盆倾斜(± 30°)的不同程度,模拟各种体位下的功能性骨盆倾斜。对于每个模拟的骨盆倾斜,手动测量髋臼杯的横向版本和冠状倾斜,并与数学模型中测量的髋臼杯进行比较,该模型中计算了髋臼杯的 3-D 位置。接下来,该模型应用于不同的髋臼杯位置,以模拟矢状位骨盆动力学对髋臼杯在冠状面和横断面上 3-D 方向的影响。骨盆倾斜后,108 个测量和计算的髋臼杯冠状和横向杯方向角度的组内相关系数分别为 0.963 和 0.990,验证了数学模型的临床应用。

结果

功能性骨盆倾斜引起的髋臼杯 3-D 方向的变化在具有不同初始位置的髋臼杯中差异很大;在功能性骨盆倾斜期间,具有低冠状倾斜度(从 50°到-29°)的髋臼杯的横向版本变化比具有正常冠状倾斜度(从 39°到-11°)或高冠状倾斜度(从 31°到 2°)的髋臼杯明显得多。然而,髋臼杯的冠状倾斜度变化在具有高横向版本的髋臼杯中更为明显。

结论

使用一种简单的算法来确定功能性矢状位骨盆倾斜期间髋臼杯的动态 3-D 重新定向,我们证明了功能性骨盆倾斜的 3-D 效应是特定于初始髋臼杯取向的,因此是每个 THA 患者的特异性。

临床相关性

未来有关 THA(内)稳定性的研究不仅应包括初始髋臼杯取向,还应包括矢状位骨盆动力学对个体 3-D 髋臼杯取向的影响。临床医生还可以使用开发的工具,www.3d-hip.com,在其他情况下计算髋臼杯的方向,例如在脊柱骨盆失衡的患者中。

相似文献

引用本文的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验