Neurosurgical Associates of Lancaster, Lancaster, PA, USA.
Center for Pain Relief, Charleston, WV, USA.
Neuromodulation. 2021 Jun;24(4):753-757. doi: 10.1111/ner.13286. Epub 2020 Oct 5.
Intraoperative neuromonitoring (IONM) has been used in the implantation of spinal cord stimulation for both safety and confirmation of lead placement. It is less well defined in its use for dorsal root ganglion (DRG) stimulator placement.
This is a retrospective analysis of 304 leads placed in 93 patients undergoing DRG stimulation therapy with its placement utilizing IONM in asleep patients by four implanting physicians in four separate centers. The first year, or early adoption period, of placements for each site was chosen as the included cases to evaluate.
There were a total of 14 IONM alerts across the 304 lead placements. There were two complications, no permanent or severe adverse events, and no revisions. All alerts led to a change in approach as a corrective action. The two complications were a patient requiring a blood patch for an undetected CSF leak, while the other was a generator site seroma that resolved with conservative care. A single patient experienced transient calf paresthesia's in the post-operative period.
This retrospective series demonstrates the utility and accuracy of IONM in not only confirming proper dorsal placement of a DRG electrode but also in maintaining a low adverse event profile. It further demonstrates that its utility in the real world with new users can be safe and accurate with an ease of integration.
术中神经监测(IONM)已被用于脊髓刺激的植入,以确保安全性和确认导丝位置。但在背根神经节(DRG)刺激器植入中的应用尚未明确。
这是对 93 名接受 DRG 刺激治疗的患者的 304 根导丝放置情况进行的回顾性分析,由 4 名分别在 4 个不同中心的植入医生在患者睡眠时使用 IONM 进行导丝放置。选择每个地点的第一年(或早期采用期)的放置情况作为纳入病例进行评估。
在 304 根导丝放置中,共发生了 14 次 IONM 报警。有 2 例并发症,无永久性或严重不良事件,也无需进行修正。所有报警均导致改变了手术方法作为纠正措施。2 例并发症中,1 例患者因未发现的脑脊液漏而需要进行血补丁治疗,另 1 例则为发生器部位血清肿,经保守治疗后缓解。1 例患者在术后出现短暂的小腿感觉异常。
本回顾性系列研究表明,IONM 不仅可确认 DRG 电极的正确背侧位置,而且可保持低不良事件发生情况,具有实用性和准确性。它进一步表明,在具有新用户的真实世界中,其易于整合,可安全且准确地应用。