Suppr超能文献

4AT 对谵妄检测的诊断准确性:系统评价和荟萃分析。

Diagnostic Test Accuracy of the 4AT for Delirium Detection: A Systematic Review and Meta-Analysis.

机构信息

College of Nursing, Korea University, Seoul 02841, Korea.

Department of Biostatistics, College of Medicine, Korea University, Seoul 02841, Korea.

出版信息

Int J Environ Res Public Health. 2020 Oct 15;17(20):7515. doi: 10.3390/ijerph17207515.

Abstract

Under-recognition of delirium is an international problem. For the early detection of delirium, a feasible and valid screening tool for healthcare professionals is needed. This study aimed to present a scientific reason for using the 4 'A's Test (4AT) through a systematic review and meta-analysis of studies on the diagnostic test accuracy. We systematically searched articles in the EMBASE, MEDLINE, CINAHL, and PsycINFO databases and selected relevant articles on the basis of the predefined inclusion criteria. The quality of the included articles was evaluated using the Quality Assessment of the Diagnostic Accuracy Studies-2 tool. We estimated the pooled values of diagnostic test accuracy by employing the bivariate model and the hierarchical summary receiver operating characteristic (HSROC) model in data synthesis. A total of 3729 patients of 13 studies were included in the analysis. The pooled estimates of sensitivity and specificity of the 4AT were 81.5% (95% confidence interval: 70.7%, 89.0%) and 87.5% (79.5%, 92.7%), respectively. Given the 4AT's evidence of accuracy and practicality, we suggest healthcare professionals to utilize this tool for routine screening of delirium. However, for detecting delirium in the dementia population, further work is required to evaluate the 4AT with other cut-off points or scoring methods in order for it to be more sensitive and specific.

摘要

谵妄识别不足是一个国际性问题。为了早期发现谵妄,需要一种可行且有效的医疗保健专业人员筛查工具。本研究旨在通过对诊断测试准确性的研究进行系统回顾和荟萃分析,为使用 4' A' s 测试(4AT)提供科学依据。我们系统地检索了 EMBASE、MEDLINE、CINAHL 和 PsycINFO 数据库中的文章,并根据预先确定的纳入标准选择了相关文章。使用诊断准确性研究质量评估工具-2 评估纳入文章的质量。我们通过使用双变量模型和分层综合受试者工作特征(HSROC)模型在数据综合中估计诊断测试准确性的汇总值。共有 13 项研究的 3729 名患者纳入分析。4AT 的敏感性和特异性的汇总估计值分别为 81.5%(95%置信区间:70.7%,89.0%)和 87.5%(79.5%,92.7%)。鉴于 4AT 的准确性和实用性证据,我们建议医疗保健专业人员将该工具用于常规谵妄筛查。然而,为了在痴呆人群中检测谵妄,需要进一步研究使用其他截断值或评分方法评估 4AT,以使其更敏感和特异。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/1ff3/7602716/22a0468db01f/ijerph-17-07515-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验