Suppr超能文献

生物瓣膜置换与机械瓣膜置换术后结局比较:一项随机试验的最初5年结果

Comparison of outcome after valve replacement with a bioprosthesis versus a mechanical prosthesis: initial 5 year results of a randomized trial.

作者信息

Hammermeister K E, Henderson W G, Burchfiel C M, Sethi G K, Souchek J, Oprian C, Cantor A B, Folland E, Khuri S, Rahimtoola S

机构信息

Cardiology Section, VA Medical Center, Denver, Colorado 80220.

出版信息

J Am Coll Cardiol. 1987 Oct;10(4):719-32. doi: 10.1016/s0735-1097(87)80263-2.

Abstract

The Veterans Administration Cooperative Study on Valvular Heart Disease was organized to compare survival and incidence of valve-related complications between patients receiving a bioprosthesis (the Hancock porcine heterograft) and a mechanical prosthesis (the Björk-Shiley spherical disc valve). Five hundred seventy-five patients undergoing single aortic or mitral valve replacement were randomized at surgery to one of the two valve types. At an average follow-up of 5 years (range 3 to 8) there are no statistically significant differences in survival between patients with the two valve types in the aortic valve replacement group. There is a statistically nonsignificant trend toward improved survival in patients undergoing mitral valve replacement with a bioprosthesis compared with a mechanical prosthesis (5 year survival probability was 0.70 +/- 0.05 and 0.58 +/- 0.06, respectively). Fatal and nonfatal valve-related complications occurred significantly less frequently in patients with a bioprosthesis compared with a mechanical prosthesis for both mitral and aortic valve replacement. Five year complication-free probability was 0.67 +/- 0.05 and 0.45 +/- 0.06, respectively, for patients with mitral valve replacement and 0.63 +/- 0.04 and 0.53 +/- 0.04, respectively, for those with aortic valve replacement. The difference in overall complication rates was largely due to the increased number of clinically significant but nonfatal bleeding episodes in patients receiving a mechanical prosthesis. Adjustment for differences in baseline characteristics between patients receiving a mitral mechanical prosthesis and a mitral bioprosthesis reduced the statistical significance of the difference in both mortality and complications.

摘要

退伍军人管理局开展了一项关于心脏瓣膜病的合作研究,旨在比较接受生物瓣膜(汉考克猪异种移植物)和机械瓣膜(比约克-希利球形瓣)的患者之间的生存率以及瓣膜相关并发症的发生率。575例接受单纯主动脉瓣或二尖瓣置换术的患者在手术时被随机分为两种瓣膜类型中的一种。在平均5年(范围3至8年)的随访中,主动脉瓣置换组中接受两种瓣膜类型的患者在生存率方面没有统计学上的显著差异。与机械瓣膜相比,接受二尖瓣置换术的患者使用生物瓣膜有生存率提高的统计学上无显著意义的趋势(5年生存概率分别为0.70±0.05和0.58±0.06)。对于二尖瓣和主动脉瓣置换术,与机械瓣膜相比,生物瓣膜患者发生致命和非致命瓣膜相关并发症的频率显著更低。二尖瓣置换术患者的5年无并发症概率分别为0.67±0.05和0.45±0.06,主动脉瓣置换术患者分别为0.63±0.04和0.53±0.04。总体并发症发生率的差异主要是由于接受机械瓣膜的患者临床上显著但非致命的出血事件数量增加。对接受二尖瓣机械瓣膜与二尖瓣生物瓣膜的患者的基线特征差异进行调整后,死亡率和并发症差异的统计学显著性降低。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验