OBJECTIVE

To evaluate the effect of slice thickness on CT perfusion analysis of the pancreas in healthy dogs.

ANIMALS

12 healthy Beagles.

PROCEDURES

After precontrast CT scans, CT perfusion scans of the pancreatic body were performed every second for 30 seconds by sequential CT scanning after injection of contrast medium (iohexol; 300 mg of 1/kg) at a rate of 3 mL/s. Each dog underwent CT perfusion scans twice in a crossover-design study with 2 different slice thicknesses (2.4 and 4.8 mm). Computed tomographic pancreatic perfusion variables, including blood flow, blood volume determined with the maximum slope model, times to the start of enhancement and peak enhancement, permeability, and blood volume determined by Patlak plot analysis, were measured independently by 2 reviewers. The CT perfusion variables were compared between slice thicknesses. Interoperator reproducibility was determined by ICC calculation.

RESULTS

Interoperator reproducibility of CT perfusion variable measurements was excellent on 2.4-mm (mean ± SD ICC, 0.81 ± 0.17) and 4.8-mm (0.90 ± 0.07) slice thicknesses, except for time to peak pancreatic enhancement on 2.4-mm-thick slices, which had moderate reproducibility (intraclass correlation coefficient, 0.473). There was no significant difference in measurements of blood flow, blood volume by either method, times to the start and peak of pancreatic enhancement, or permeability between slice thicknesses.

CONCLUSIONS AND CLINICAL RELEVANCE

Results supported that a thin slice thickness of 2.4 mm can be used for assessment of pancreatic perfusion variables in healthy dogs.

摘要

目的

评估层厚对健康犬胰腺CT灌注分析的影响。

动物

12只健康的比格犬。

方法

在进行平扫CT扫描后,以3 mL/s的速率注射造影剂(碘海醇;300 mg碘/千克),然后通过序列CT扫描每秒对胰腺体部进行一次CT灌注扫描,持续30秒。在一项交叉设计研究中,每只犬使用两种不同层厚(2.4和4.8 mm)进行两次CT灌注扫描。由两名阅片者独立测量CT胰腺灌注变量,包括血流量、用最大斜率模型测定的血容量、开始强化时间和峰值强化时间、通透性以及通过Patlak图分析测定的血容量。比较不同层厚之间的CT灌注变量。通过计算组内相关系数(ICC)确定阅片者间的可重复性。

结果

除了2.4 mm厚层面的胰腺峰值强化时间具有中等可重复性(组内相关系数为0.473)外,CT灌注变量测量在2.4 mm(平均±标准差ICC,0.81±0.17)和4.8 mm(0.90±0.07)层厚上的阅片者间可重复性良好。不同层厚之间在血流量、两种方法测定的血容量、胰腺强化开始和峰值时间或通透性的测量上没有显著差异。

结论及临床意义

结果支持2.4 mm的薄层厚可用于评估健康犬的胰腺灌注变量。