We evaluated three different methods for measuring lactate dehydrogenase (EC 1.1.1.27) isoenzyme LD-1 activity--agarose gel electrophoresis and two immunoassays, Isomune-LD (Roche) and LD-1 Immuno (Seragen)--in patients' samples for which measurement of creatine kinase-MB was ordered. Regression analyses of the comparisons gave the following results: LD-1 (%) from Isomune-LD (y) vs electrophoresis (x) (n = 51), y = 1.05x + 1.99, r = 0.92; LD-1 (%) from LD-1 Immuno (y) vs electrophoresis (n = 27), y = 1.05x + 3.94, r = 0.88; LD-1 (%) from LD-1 Immuno (y) vs Isomune-LD (x) (n = 41), y = 1.06x + 0.48, r = 0.95. Comparison by Student's paired t-test yielded significant differences between the mean values by electrophoresis and both Isomune-LD (P less than 0.005) and LD-1 Immuno (P less than 0.001), but no significant difference between the two immunoassays (P greater than 0.2). Analyzing these results by the overlap index, we conclude that electrophoresis shows the best clinical correlation followed, in order, by the Isomune-LD and the LD-1 Immuno methods. Both immunoassays are simpler and more rapid than electrophoresis, but in our hands the Isomune-LD method demonstrated greater precision and better correlation with electrophoretic values.

摘要

我们评估了三种不同的方法来测量乳酸脱氢酶(EC 1.1.1.27)同工酶LD - 1的活性——琼脂糖凝胶电泳以及两种免疫测定法,即Isomune - LD(罗氏公司)和LD - 1 Immuno(Seragen),用于对已下达肌酸激酶 - MB检测医嘱的患者样本进行检测。对这些比较结果进行回归分析得出以下结果:Isomune - LD检测的LD - 1(%)(y)与电泳检测结果(x)(n = 51)相比,y = 1.05x + 1.99,r = 0.92;LD - 1 Immuno检测的LD - 1(%)(y)与电泳检测结果(n = 27)相比,y = 1.05x + 3.94,r = 0.88;LD - 1 Immuno检测的LD - 1(%)(y)与Isomune - LD检测结果(x)(n = 41)相比,y = 1.06x + 0.48,r = 0.95。采用学生配对t检验进行比较,结果显示电泳法与Isomune - LD(P < 0.005)和LD - 1 Immuno(P < 0.001)的平均值之间存在显著差异,但两种免疫测定法之间无显著差异(P > 0.2)。通过重叠指数分析这些结果,我们得出结论,电泳法显示出最佳的临床相关性,其次依次是Isomune - LD法和LD - 1 Immuno法。两种免疫测定法都比电泳法更简单、更快速,但在我们的操作中,Isomune - LD法显示出更高的精密度以及与电泳值更好的相关性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验