Suppr超能文献

评估前列腺素类似物使用与眼内压和前房容积的关系。

Evaluating the Relationship of Intraocular Pressure and Anterior Chamber Volume With Use of Prostaglandin Analogues.

机构信息

Departments of Ophthalmology & Vision Sciences.

Biomedical Engineering, Havener Eye Institute, The Ohio State University Wexner Medical Center, Columbus, OH.

出版信息

J Glaucoma. 2021 May 1;30(5):421-427. doi: 10.1097/IJG.0000000000001736.

Abstract

PRCIS

In this prospective study, naive prostaglandin use in primary open-angle glaucoma was associated with scleral biomechanical alteration and intraocular pressure (IOP) measuring errors.

PURPOSE

The purpose of this study is to determine the effects of naïve use of prostaglandin analogues (PGA) on IOP and anterior chamber volume (ACV), as well as investigate how PGAs might affect corneal and scleral stiffness and their impact on ocular rigidity.

MATERIALS AND METHODS

This study was a prospective study of 21 recently diagnosed open-angle glaucoma patients (33 eyes) initiating medical therapy with a topical prostaglandin eye drop. Corneal morphologic and biomechanical parameters as well as IOP were measured at 3 visits over a 4-month period with the following equipment: Pentacam, Corvis ST, Ocular Response Analyzer, Goldmann applanation tonometry (GAT) and Pascal dynamic contour tonometry.

RESULTS

The study demonstrated a significant decrease in mean IOP with initiation of PGA in all 4 tonometers (P<0.0001). The greatest change in IOP occurred in the first 4 weeks of treatment (P<0.0001). The mean ACV showed a significant decrease at visit 2 (P<0.02) and visit 3 (P<0.04) compared with baseline visit 1. However, there was a paradoxical increase in ACV in 37% of eyes at visit 2, despite a significant mean reduction in IOP by GAT and dynamic contour tonometry.The IOP/ACV ratio at visit 1 significantly predicted the reduction in respective measures of IOP, as well as scleral stiffness measured by stiffness parameter-highest concavity.

CONCLUSION

In clinical practice, GAT may not be the most appropriate tonometer for measuring IOP in PGA treated eyes due the measurement errors from ocular biomechanical alteration. The IOP/ACV ratio could potentially serve as a new diagnostic parameter to determine the likelihood of PGA treatment success.

摘要

PRCIS

在这项前瞻性研究中,原发性开角型青光眼患者初次使用前列腺素类药物与巩膜生物力学改变和眼压(IOP)测量误差有关。

目的

本研究旨在确定初次使用前列腺素类似物(PGA)对IOP 和前房容积(ACV)的影响,并探讨 PGA 如何影响角膜和巩膜的硬度及其对眼内刚性的影响。

材料和方法

这是一项前瞻性研究,纳入 21 例新诊断的开角型青光眼患者(33 只眼),他们开始接受局部前列腺素滴眼剂治疗。在 4 个月的 3 次就诊期间,使用 Pentacam、Corvis ST、Ocular Response Analyzer、Goldmann 压平眼压计(GAT)和 Pascal 动态轮廓眼压计测量角膜形态和生物力学参数以及 IOP。

结果

本研究显示,所有 4 种眼压计在开始使用 PGA 后,平均 IOP 均显著下降(P<0.0001)。治疗的前 4 周 IOP 变化最大(P<0.0001)。与基线第 1 次就诊相比,第 2 次(P<0.02)和第 3 次(P<0.04)就诊时平均 ACV 显著下降。然而,在第 2 次就诊时,37%的眼出现 ACV 反常增加,尽管 GAT 和动态轮廓眼压计测量的平均 IOP 显著降低。第 1 次就诊时的 IOP/ACV 比值显著预测了各自 IOP 测量值以及由硬度参数-最大凹陷测量的巩膜硬度的降低。

结论

在临床实践中,由于眼生物力学改变导致测量误差,GAT 可能不是测量 PGA 治疗眼 IOP 的最适当眼压计。IOP/ACV 比值可能是一种新的诊断参数,可用于确定 PGA 治疗成功的可能性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验