Suppr超能文献

评价使用新型热处理镍钛器械在弯曲根管预备时根管内的切削碎屑。

Evaluation of apically extruded debris during the canal preparation using new heat-treated nickel-titanium files in curved canals.

机构信息

Department of Endodontics, Faculty of Dentistry, Erciyes University, Kayseri, Turkey.

出版信息

Aust Endod J. 2021 Apr;47(1):54-58. doi: 10.1111/aej.12459. Epub 2020 Nov 7.

Abstract

This study compared the amount of apically extruded debris associated with different heat-treated Ni-Ti rotary systems during the preparation of curved root canals of mandibular molars. Sixty extracted human mandibular molars were selected. EdgeFile, K3XF, OneCurve (OC) and ROTATE files were used to prepare both mesial canals of teeth. The initial weight of each Eppendorf tube to be used was calculated using an analytical balance prior to instrumentation. After instrumentation, the tubes were then stored for 5 days in an incubator at 70°C. Each tube was reweighed, and the weight of the dry extruded debris was established by subtracting the pre-instrumentation and post-instrumentation weight of the Eppendorf tubes for each group. All files caused apical extrusion of debris. There was no statistical difference between the ROTATE, EdgeFile, OC and K3XF systems (P > 0.05). All the heat-treated Ni-Ti rotary systems led to similar apical debris extrusion during the canal preparation.

摘要

本研究比较了不同热处理镍钛旋转系统在预备下颌磨牙弯曲根管时根尖挤出的碎屑量。选择 60 颗离体下颌磨牙。EdgeFile、K3XF、OneCurve(OC)和 ROTATE 锉用于预备牙齿的近中根管。在器械预备前,使用分析天平计算每个用于的 Eppendorf 管的初始重量。器械预备后,将管在 70°C 的孵育器中储存 5 天。每个管重新称重,并通过从每组 Eppendorf 管的器械预备前和器械预备后的重量中减去来确定干燥挤出的碎屑的重量。所有的锉都导致了根尖碎屑的挤出。ROTATE、EdgeFile、OC 和 K3XF 系统之间没有统计学差异(P>0.05)。在根管预备过程中,所有热处理镍钛旋转系统均导致类似的根尖碎屑挤出。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验