Suppr超能文献

经皮胆红素检测在诊断黄疸新生儿高胆红素血症中的准确性。

The accuracy of transcutaneous bilirubin to identify hyperbilirubinemia in jaundiced neonates.

机构信息

Obstetrics & Gynecology Hospital Affiliated to Fudan University, Shanghai, China.

出版信息

J Matern Fetal Neonatal Med. 2022 Nov;35(22):4318-4325. doi: 10.1080/14767058.2020.1849112. Epub 2020 Nov 19.

Abstract

OBJECTIVE

To compare transcutaneous bilirubin (TcB) to total serum bilirubin (TSB) in jaundiced neonates by using a JM-103 bilirubinometer.

METHODS

We conducted a retrospective study in jaundiced infants ≥35 weeks' gestation. Infants' and maternal information, TcB measurements, and TSB levels were collected. The correlation and consistency between TcB and TSB were analyzed by Pearson's correlation analysis and the Bland-Altman plot. Multivariate regression analysis was used to identify characteristics associated with the difference between TcB and TSB, underestimation by TcB and overestimation by TcB.

RESULTS

A total of 787 paired samples were collected. There was a strong correlation between TcB and TSB with a Pearson correlation coefficient of 0.708 ( < .001). In preterm infants, outpatients and infants with high TSB levels, the TcB measurements were less precise. The TcB-TSB difference was significantly associated with gender, maternal hypertension disease, ABO hemolytic disease, and outpatient setting ( < .05). Only the outpatient setting had statistical significance in the underestimation of TSB ≥2 mg/dL.

CONCLUSIONS

Generally, TcB by a JM-103 bilirubinometer had a good correlation and consistency with the TSB values. However, small for gestational age, postnatal age of hour, ABO hemolytic disease, and outpatient setting may lead to inconsistencies between the TcB and TSB.

摘要

目的

使用 JM-103 经皮胆红素仪比较黄疸新生儿的经皮胆红素(TcB)与总血清胆红素(TSB)。

方法

我们对胎龄≥35 周的黄疸婴儿进行了回顾性研究。收集了婴儿和产妇的信息、TcB 测量值和 TSB 水平。通过 Pearson 相关分析和 Bland-Altman 图分析 TcB 与 TSB 之间的相关性和一致性。采用多元回归分析确定与 TcB 和 TSB 之间差异、TcB 低估和 TcB 高估相关的特征。

结果

共收集了 787 对样本。TcB 与 TSB 之间具有很强的相关性,Pearson 相关系数为 0.708(<0.001)。在早产儿、门诊患者和 TSB 水平较高的婴儿中,TcB 测量值的精度较低。TcB-TSB 差异与性别、产妇高血压疾病、ABO 溶血病和门诊设置显著相关(<0.05)。只有门诊设置在 TSB≥2mg/dL 低估方面具有统计学意义。

结论

一般来说,JM-103 经皮胆红素仪的 TcB 与 TSB 值具有良好的相关性和一致性。然而,小于胎龄、生后小时、ABO 溶血病和门诊设置可能导致 TcB 与 TSB 之间的不一致。