Suppr超能文献

原发性手掌多汗症患者交感皮肤反应的测试内信度。

Intra tester reliability of sympathetic skin responses in subjects with primary palmar hyperhidrosis.

机构信息

Department of Physiotherapy, School of Rehabilitation, Student Research Committee, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

Department of Physiotherapy, School of Rehabilitation, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

出版信息

J Bodyw Mov Ther. 2020 Oct;24(4):57-62. doi: 10.1016/j.jbmt.2020.02.024. Epub 2020 Feb 26.

Abstract

BACKGROUND

Primary palmar hyperhidrosis (PPH) is a disorder related to sympathetic dysfunction. Iontophoresis can be used to reduce sweating rate. Sympathetic skin response (SSR) is commonly used to evaluate the sympathetic system. However, scarce evidence exists about the reliability of SSR parameters.

OBJECTIVE

To assess the relative and absolute reliability of SSR before and after the application of iontophoresis with aluminum chloride hexahydrate (ACH) gel or tap water in subjects with PPH.

METHODS

Twenty subjects were randomized to receive either iontophoresis with ACH gel or tap water. Three SSRs (amplitude and latency) with 5 s intervals from both hands in both groups were recorded before and after the application of iontophoresis for 30 min. Reliability of amplitude and latency of the SSR was assessed using intraclass correlation coefficient (ICC) with 95% confidence intervals, standard error of measurement (SEM), and minimal detectable change (MDC).

RESULTS

Amplitudes and latencies of SSR showed good to excellent test-retest reliability for ICC in both groups before iontophoresis. Except for right hand latency which was moderate (0.5-0.75). After iontophoresis, the ACH gel group still showed good to excellent agreement for SSR parameters, while the reliability of SSR parameters in the tap water group was reduced.

CONCLUSION

Subjects with PPH showed high intra-rater reliability for SSR parameters which was maintained after ACH gel iontophoresis and decreased after tap water iontophoresis. It seems that media used for iontophoresis or the state of media (gel vs liquid) may affect the reliability of SSR. Further research is recommended.

摘要

背景

原发性手掌多汗症(PPH)是一种与交感神经功能障碍有关的疾病。离子电渗疗法可用于降低出汗率。交感皮肤反应(SSR)常用于评估交感神经系统。然而,SSR 参数的可靠性证据很少。

目的

评估 PPH 患者应用六水合氯化铝(ACH)凝胶或自来水进行离子电渗治疗前后 SSR 的相对和绝对可靠性。

方法

将 20 名受试者随机分为接受 ACH 凝胶或自来水离子电渗治疗的两组。在离子电渗治疗 30 分钟前后,每组从双手记录 3 个 SSR(振幅和潜伏期),间隔 5 秒。使用组内相关系数(ICC)及其 95%置信区间、测量误差(SEM)和最小可检测变化(MDC)评估 SSR 振幅和潜伏期的可靠性。

结果

在离子电渗治疗前,两组的 SSR 振幅和潜伏期的 ICC 均具有良好到极好的测试-重测可靠性。除了右手潜伏期为中度(0.5-0.75)。离子电渗治疗后,ACH 凝胶组的 SSR 参数仍具有良好到极好的一致性,而自来水组的 SSR 参数可靠性降低。

结论

PPH 患者的 SSR 参数具有高内部可靠性,ACH 凝胶离子电渗治疗后保持不变,自来水离子电渗治疗后降低。似乎离子电渗治疗中使用的介质或介质状态(凝胶与液体)会影响 SSR 的可靠性。建议进一步研究。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验