Int J Pharm. 2021 Jan 25;593:120103. doi: 10.1016/j.ijpharm.2020.120103. Epub 2020 Nov 23.
Quantifying drug delivery to the site of action using locally-acting nasal suspension sprays is a challenging but important step toward understanding bioequivalence (BE) between test and reference products. The main objective of this study was to investigate the in vitro deposition pattern of two common but different locally-acting nasal suspension sprays using multiple nasal cavities. Twenty anatomically accurate nasal replicas were developed from high-resolution sinonasal computed tomography scans of adults with healthy nasal airways. The airways were segmented into two regions of anterior and posterior to the internal nasal valve. Both sides of the septum were considered separately; hence, 40 nasal cavities were studied. The positioning of the spray nozzle in all 40 cavities was characterized by the head angle, coronal angle, and the insertion depth. Despite using a controlled protocol to minimize the anterior losses, a wide range of variability in posterior drug delivery was observed. The observed intersubject variability using this in vitro method may have important implications for understanding BE of locally-acting nasal suspension sprays.
使用局部作用的鼻腔混悬喷雾剂来定量药物递送至作用部位是理解试验品和参比品之间生物等效性(BE)的一个具有挑战性但很重要的步骤。本研究的主要目的是使用多个鼻腔来研究两种常见但不同的局部作用鼻腔混悬喷雾剂的体外沉积模式。从具有健康鼻腔气道的成年人的高分辨率鼻窦计算机断层扫描中开发了 20 个解剖精确的鼻腔复制品。气道被分为内部鼻阀前后两个区域。鼻中隔的两侧分别考虑;因此,研究了 40 个鼻腔。通过头角、冠状角和插入深度来描述所有 40 个腔中的喷雾喷嘴的定位。尽管使用了控制方案来最小化前损失,但仍观察到后向药物递送的广泛变异性。使用这种体外方法观察到的个体间变异性可能对理解局部作用的鼻腔混悬喷雾剂的 BE 具有重要意义。