Department of Orthopaedics and Traumatology, Istanbul Training and Research Hospital, Istanbul, Turkey.
Department of Orthopaedics and Traumatology, Faculty of Medicine, University of Kyrenia, Kyrenia, Cyprus.
Knee. 2020 Dec;27(6):1980-1987. doi: 10.1016/j.knee.2020.10.008. Epub 2020 Nov 25.
This study aimed to investigate the possible consequences of soft tissue interposition of Endobutton on clinical outcomes and reoperation rates after anterior cruciate ligament reconstruction.
We measured the distance between the centre of the Endobutton and the lateral femoral cortex on the postoperative first day anteroposterior X-rays of the 156 knees that underwent anterior cruciate ligament reconstruction. Those with a distance less than 1 mm were regarded as Group 1 (118 patients), the ones between 1 mm and 2 mm were regarded as Group 2 (30 patients) and the ones more than 2 mm were regarded as Group 3 (8 patients). The movement of the Endobutton of more than 1 mm along the femoral tunnel axis on anteroposterior X-rays or its rotation by more than 5° on lateral X-rays during follow-up were considered migration. Clinical assessment scores (Lysholm, Tegner Activity Scale), clinical examination tests, and rates of Endobutton migration in the groups were analysed.
Eleven Endobuttons (9.3%) in Group 1, 26 Endobuttons (86.7%) in Group 2 and all of the 8 Endobuttons (100%) in Group 3 were observed to have migrated. Clinical results and examination tests showed no significant difference between Groups 1 and 2, whereas a significant difference was detected in Group 3 compared to Groups 1 and 2 (p < 0.05).
Soft tissue interposition is a major cause of Endobutton migration, and an interposition over 2 mm between the Endobutton and the lateral femoral cortex can negatively affect the outcomes after an anterior cruciate ligament surgery.
本研究旨在探讨前交叉韧带重建术后,Endobutton 周围软组织嵌塞对临床结果和再手术率的可能影响。
我们测量了 156 例接受前交叉韧带重建术患者术后第 1 天前后位 X 线片上 Endobutton 中心与股骨外侧皮质之间的距离。距离小于 1mm 的患者归为第 1 组(118 例),距离在 1mm 至 2mm 之间的患者归为第 2 组(30 例),距离大于 2mm 的患者归为第 3 组(8 例)。随访中前后位 X 线片上 Endobutton 沿股骨隧道轴移动超过 1mm 或侧位 X 线片上旋转超过 5°,则认为发生了迁移。分析各组的临床评估评分(Lysholm、Tegner 活动量表)、临床检查试验和 Endobutton 迁移率。
第 1 组中有 11 个 Endobutton(9.3%)、第 2 组中有 26 个 Endobutton(86.7%)和第 3 组中的全部 8 个 Endobutton(100%)发生了迁移。第 1 组和第 2 组的临床结果和检查试验无显著差异,而第 3 组与第 1 组和第 2 组相比差异显著(p<0.05)。
软组织嵌塞是 Endobutton 迁移的主要原因,Endobutton 与股骨外侧皮质之间的间隔超过 2mm 会对前交叉韧带手术后的结果产生负面影响。