Aachen Center of Technology Transfer in Ophthalmology (ACTO E.V.), An-Institute RWTH Aachen University, Karlsburgweg 9, 52070, Aachen, Germany.
University of Applied Sciences Ansbach, Ansbach, Germany.
Sci Rep. 2020 Dec 10;10(1):21710. doi: 10.1038/s41598-020-78878-y.
To examine the applicability of plasma-mediated vitreous body removal, a diode-pumped Q-switched Neodymium:YAG laser was used for a possible application in eye surgery/vitrectomy. On a total of 1500 porcine vitreous bodies, removal rates were evaluated by comparing different LaserVit-tip designs (Mark I/II Gauge 19 and Mark III Gauge 22). The Nd:YAG laser, operating at a wavelength of 1064 nm and a pulse duration of 4 ns, was utilized for vitreous body removal with respective settings of 2, 3 and 4 mJ and pulse repetition rates (cut rates) from 5 to 25 Hz (300-1500 /min) in 5 Hz-steps as well as for 100 Hz (6000 cuts/min). The exposure times were selected at 10, 20, 40 and 60 s, respectively. Comparative measurements were carried out with mechanical cutters (Gauge 20 and Gauge 23), applying a fixed cut rate of 800 /min (13.33 Hz) at identical exposure times. The LaserVit-tips showed successful vitreous body removal for all laser settings and exposure times (Mark I: 6.2 g/min, Mark II: 8.2 g/min at 1500 cuts/min and 3 mJ, Mark II: 10.1 g/min, Mark III: 3.6 g/min at 6000 cuts/min at 3 mJ). Similar tip-dimensions (Gauge 22 and Gauge 23) showed comparable removal rates of 3.6 g/min and 1.3 g/min with settings of 6000 cuts/min at 3 mJ (laser) and 800 cuts/min for the mechanical cutter. A diode-pumped Q-switched Nd:YAG laser can successfully and gently remove vitreous body. The efficiency of the laser was comparable to that of mechanical cutters in terms of quantity of material removed per time unit.
为了检验等离子体玻璃体切除的适用性,我们使用二极管泵浦 Q 开关掺钕钇铝石榴石(Nd:YAG)激光在眼外科/玻璃体切除术中进行了潜在应用。在总共 1500 个猪玻璃体中,通过比较不同的 LaserVit 尖端设计(Mark I/II 规格 19 和 Mark III 规格 22)来评估去除率。Nd:YAG 激光的波长为 1064nm,脉冲持续时间为 4ns,用于玻璃体切除,激光能量分别为 2、3 和 4mJ,脉冲重复率(切割率)为 5 至 25Hz(300-1500 次/分钟),以 5Hz 为步长,100Hz(6000 次/分钟)。曝光时间分别选择为 10、20、40 和 60s。用机械切割器(规格 20 和规格 23)进行了对比测量,在相同的曝光时间内应用固定的切割率 800 次/分钟(13.33Hz)。对于所有的激光设置和曝光时间,LaserVit 尖端都成功地去除了玻璃体(Mark I:1500 次/分钟和 3mJ 时为 6.2g/min,Mark II:1500 次/分钟和 3mJ 时为 8.2g/min,Mark II:10.1g/min,Mark III:3mJ 和 6000 次/分钟时为 3.6g/min)。类似的尖端尺寸(规格 22 和规格 23)在 3mJ 和 6000 次/分钟的激光设置以及 3mJ 和 800 次/分钟的机械切割器的设置下,去除率分别为 3.6g/min 和 1.3g/min,结果相当。二极管泵浦 Q 开关掺钕钇铝石榴石激光可以成功且轻柔地去除玻璃体。从单位时间内去除的材料量来看,激光的效率与机械切割器相当。