• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Background in the 99mTc DTPA renogram: analysis of intravascular and extravascular components.

作者信息

Peters A M, Gordon I, Evans K, Todd-Pokropek A

机构信息

Department of Paediatric Radiology, Hospital for Sick Children, London, England.

出版信息

Am J Physiol Imaging. 1987;2(2):67-71.

PMID:3330450
Abstract

Individual kidney glomerular filtration rate (IKGFR) was calculated from the upslope of the 99mTc-diethylenetriamine pentaacetic acid (DTPA) renogram in ten children with a normal solitary kidney (on the right in five and on the left in five). By using a method of renogram analysis that is independent of the intravascular (IV) component of background (BG) activity, the IV and extravascular (EV) components of background were separately quantified in various regions in proximity to the nephrectomy site. The size of the IV compartment was expressed as an absolute plasma volume (PV-BG), and that of the EV compartment was expressed as a "GFR equivalent," i.e., the undirectional rate of fluid transfer from the IV to EV spaces in ml per min (GFR-BG). The region areas from which these parameters were calculated were normalised to the area projected by the solitary kidney. In a region centred over the lower pole of the imagined absent kidney, PV-BG was 129 +/- 7 ml (SE) and GFR-BG was 28 +/- 1.8 ml per min. The corresponding values centred over the liver/spleen on the nephrectomised side were 353 +/- 24 ml and -2 +/- 2.9 ml per min, respectively. PV-BG, but not GFR-BG, was significantly higher over the liver (397 ml and -6.8 +/- 1.5 ml per min) compared with the spleen (287 ml, P less than .05; and 4.5 +/- 3.2 ml per min, P greater than .05). PV-BG and GFR-BG in a region placed over the centre of the nephrectomy site were intermediate between those superior and inferior: 231 +/- 17 ml and 15 +/- 2.7 ml per min, respectively. The IV signal rises while the EV falls during the second phase of the renogram. In the analysis of the renogram during this phase, therefore, background should be based on both supra- and subrenal regions of interest.

摘要

相似文献

1
Background in the 99mTc DTPA renogram: analysis of intravascular and extravascular components.
Am J Physiol Imaging. 1987;2(2):67-71.
2
Background in 99Tcm DTPA renography evaluated by the impact of its components on individual kidney glomerular filtration rate.
Nucl Med Commun. 1988 Aug;9(8):545-52. doi: 10.1097/00006231-198808000-00003.
3
Measurement of the ratio of glomerular filtration rate to plasma volume from the technetium-99m diethylene triamine pentaacetic acid renogram: comparison with glomerular filtration rate in relation to extracellular fluid volume.利用锝-99m二乙三胺五乙酸肾图测量肾小球滤过率与血浆容量之比:与肾小球滤过率相对于细胞外液容量的比较。
Eur J Nucl Med. 1994 Apr;21(4):322-7. doi: 10.1007/BF00947967.
4
Appropriate selection of background for 99Tcm-DTPA renography.99锝-二乙三胺五醋酸肾动态显像背景的合理选择。
Nucl Med Commun. 1988 Dec;9(12):973-85. doi: 10.1097/00006231-198812000-00006.
5
Three-hour volume of distribution method: an accurate simplified method of glomerular filtration rate measurement.
J Nucl Med. 1987 Apr;28(4):510-3.
6
Measurement of glomerular filtration rate with technetium-99m DTPA: comparison of plasma clearance techniques.用锝-99m二乙三胺五乙酸测量肾小球滤过率:血浆清除技术的比较。
J Nucl Med. 1987 Mar;28(3):372-7.
7
Evaluation of glomerular filtration rate by camera-based method in both children and adults.基于摄像头的方法在儿童和成人中评估肾小球滤过率
J Nucl Med. 1998 Oct;39(10):1784-8.
8
Assessment of the rate of uptake-plasma volume product to calculate glomerular filtration rate [corrected].评估摄取量-血浆容量乘积率以计算肾小球滤过率[校正后] 。
J Nucl Med. 1995 Sep;36(9):1602-4.
9
99mTc-DTPA scintillation-camera renography: a new method for estimation of single-kidney function.99m锝-二乙三胺五乙酸闪烁照相机肾造影术:一种评估单肾功能的新方法。
J Nucl Med. 1977 Feb;18(2):112-7.
10
Estimation of total and individual kidney GFR with 99m technetium DTPA.
J Assoc Physicians India. 1987 Apr;35(4):271-3.

引用本文的文献

1
Relative Ectopic Kidney Function Quantification Using DMSA Tomoscintigraphy Modality.应用 DMSA 闪烁扫描技术定量评估相对异位肾功能。
J Healthc Eng. 2020 May 26;2020:6092305. doi: 10.1155/2020/6092305. eCollection 2020.
2
Validation of the full-age spectrum equation in the approximation of glomerular filtration rate in Chinese patients with chronic kidney disease.验证全年龄段方程在估算中国慢性肾脏病患者肾小球滤过率中的适用性。
Ren Fail. 2019 Nov;41(1):467-472. doi: 10.1080/0886022X.2019.1620773.
3
Guidelines for standard and diuretic renogram in children.
儿童标准及利尿肾动态显像指南。
Eur J Nucl Med Mol Imaging. 2011 Jun;38(6):1175-88. doi: 10.1007/s00259-011-1811-3.