Wrist range of motion (ROM) is considered the universal measurement of success for both surgical and non-surgical treatments. A goniometer can be challenging for an individual to use by themselves, whereas the Dartfish app can analyze and provide immediate feedback to monitor and evaluate patients' kinematic changes during recovery after injury.
To establish the validity and reliability of the Dartfish app measuring ROM to be used in clinical applications.
Twelve healthy participants, (18-25 yrs) , with no previous history of wrist injuries, were recruited for this study. Flexion/extension, radial/ulnar deviation, and supination/pronation range of motion measures were collected using a goniometer (two-arm) and Dartfish video analysis. Statistical analyses, such as t-tests and the Pearson correlation coefficient, as well as reliability analyses, such as intraclass correlation coefficient (ICC) and Bland-Altman plots, were performed.
There was no significant difference between the goniometer and Dartfish ROM measurements except for ulnar deviation. The concurrent validity showed nearly perfect correlations between examiners using Dartfish with r-values in the range 0.90-0.99, and between examiner2 and the goniometer showed medium, large, and very large correlations since the values were in the range 0.418-0.829. The ICC for test-retest reliability had an excellent agreement that ranged from 0.993-0.999, and the ICC values for inter-observer reliability had good and excellent agreement, which were in the range 0.893-0.997.
Overall, the results demonstrated that the Dartfish app was a reliable and valid method to measure wrist and forearm ROM. A patient would be able to easily record their own ROM measurement videos and track their progress during their recovery without the need of their physician to track their progress.
临床测量。
手腕活动范围(ROM)被认为是手术和非手术治疗成功的通用衡量标准。个体使用量角器可能具有挑战性,而 Dartfish 应用程序可以分析并提供即时反馈,以监测和评估患者受伤后康复期间的运动学变化。
确定 Dartfish 应用程序测量 ROM 在临床应用中的有效性和可靠性。
本研究招募了 12 名健康参与者(18-25 岁),他们没有手腕受伤的既往史。使用量角器(双臂)和 Dartfish 视频分析收集了屈/伸、桡/尺偏和旋前/旋后活动范围测量值。进行了统计分析,如 t 检验和 Pearson 相关系数,以及可靠性分析,如组内相关系数(ICC)和 Bland-Altman 图。
除了尺侧偏,量角器和 Dartfish ROM 测量值之间没有显著差异。使用 Dartfish 的两位评估者的同时效度显示出近乎完美的相关性,r 值在 0.90-0.99 之间,评估者 2 与量角器之间的相关性显示出中度、高度和非常高度的相关性,因为值在 0.418-0.829 之间。测试 - 重测可靠性的 ICC 具有极好的一致性,范围为 0.993-0.999,观察者间可靠性的 ICC 值具有良好和极好的一致性,范围为 0.893-0.997。
总体而言,结果表明 Dartfish 应用程序是一种可靠且有效的测量手腕和前臂 ROM 的方法。患者无需医生跟踪其进展,就能够轻松记录自己的 ROM 测量视频并跟踪其康复过程中的进展。