Istanbul University-Cerrahpasa, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Büyükçekmece Yerleşkesi Alkent 2000 Mah., Yiğittürk Cad. No:5/9/1, Büyükçekmece/İstanbul, Turkey.
Istanbul Medeniyet University, Faculty of Engineering and Natural Sciences, Department of Computer Engineering, Kuzey Yerleşkesi H Blok, Ünalan Mah., Ünalan Sok, D100 Karayolu yanyol, 34700 Üsküdar/İstanbul, Turkey.
Hand Surg Rehabil. 2021 Sep;40(4):394-399. doi: 10.1016/j.hansur.2021.03.007. Epub 2021 Mar 26.
The present study aimed to validate the Leap Motion Controller (LMC)-based Fizyosoft® HandROM System developed by our team to evaluate range of motion (ROM) for fingers, wrist, and forearm in a new clinical setting. Thirty-five healthy individuals participated in the study (all right-handed, 20-30 years old). The LMC-based Fizyosoft® HandROM System is a licensed software ROM-measurement developed by our team. Pronation/supination, wrist flexion/extension, ulnar/radial deviation and metacarpophalangeal (MCP) flexion/extension of all fingers were measured with both the Fizyosoft® HandROM System and a universal goniometer. No significant differences were found between the two measurement methods for almost all mean ROMs except for ulnar and radial deviation (p > 0.05). Highly significant correlations were found between all ROMs of the forearm, wrist, and thumb (p < 0.01). MCP flexion showed significant correlation only in the index finger (r = 0.516, p = 0.003) and little finger (r = 0.517, p = 0.004). Besides, for both measures, the intraclass correlations were good to excellent on all ROMs of the forearm, wrist, and fingers except for MCP of the middle and ring fingers (0.68-0.88). The present study results indicated that the LMC-based Fizyosoft® HandROM System could sensitively track changes in the active motion of the thumb, wrist, and forearm. It is a viable alternative for assessing ROMs of the forearm, wrist, and thumb in patient follow-up.
本研究旨在验证我们团队开发的基于 Leap Motion Controller(LMC)的 Fizyosoft® HandROM 系统,以在新的临床环境中评估手指、手腕和前臂的活动范围(ROM)。35 名健康个体参与了这项研究(均为右利手,年龄 20-30 岁)。基于 LMC 的 Fizyosoft® HandROM 系统是我们团队开发的一款获得许可的软件 ROM 测量系统。使用 Fizyosoft® HandROM 系统和通用量角器测量所有手指的旋前/旋后、腕关节屈伸、尺侧/桡侧偏斜以及掌指关节(MCP)屈伸。除了尺侧和桡侧偏斜(p > 0.05)外,两种测量方法的几乎所有平均 ROM 之间均无显著差异。前臂、手腕和拇指的所有 ROM 之间均存在高度显著的相关性(p < 0.01)。MCP 屈曲仅在食指(r = 0.516,p = 0.003)和小指(r = 0.517,p = 0.004)中与其他 ROM 具有显著相关性。此外,对于两种测量方法,除了中指和环指的 MCP(0.68-0.88)外,前臂、手腕和手指的所有 ROM 的组内相关系数均良好到极好(0.68-0.88)。本研究结果表明,基于 LMC 的 Fizyosoft® HandROM 系统能够灵敏地跟踪拇指、手腕和前臂主动运动的变化。它是评估前臂、手腕和拇指 ROM 的一种可行替代方法,适用于患者随访。