This reports covers the application to paediatrics of total IgE determination by the means of a new direct, sandwich type, fluorescence enzyme immuno-assay (Fluoro-allergo sorbent test:FAST IgE). The technical process is adapted for usual determinations, in case of infants and young children, of low normal rates with a good sensitivity, and of high pathological rates. IgE total usual values are established by the FAST IgE test from serums of healthy children, aged from one day to 14 years. Seven age groups are to be distinguished.

摘要

本报告涵盖了一种新型直接夹心式荧光酶免疫测定法(荧光变应原吸附试验:FAST IgE)在儿科中总IgE测定的应用。该技术流程适用于婴幼儿低正常水平、高病理水平的常规测定,且灵敏度良好。通过FAST IgE试验,从1日龄至14岁健康儿童的血清中确定总IgE的常规值。需区分七个年龄组。