Suppr超能文献

比较楚氏测量规与 T 形尖端测规和双尖测规在一组波多黎各人前牙牙体测量中的应用。

Comparison of Chu's Proportion Gauge with a T-bar Tip and a Two-Tip Compass in the Determination of Anterior Dentition Tooth Size in a Group of Puerto Ricans.

机构信息

Office of the Assistant Dean of Research, School of Dental Medicine, University of Puerto Rico Medical Sciences Campus, San Juan, Puerto Rico.

Department of Surgery, School of Medicine, University of Puerto Rico Medical Sciences Campus, San Juan, Puerto Rico.

出版信息

P R Health Sci J. 2020 Dec;39(4):288-293.

Abstract

OBJECTIVE

Compare maxillary anterior dentition measurements, using Chu's proportion gauge with a T-bar tip (PG-TT) and a Two-Tip Compass (T-TC), in a group of Puerto Ricans, to determine the reliability of the PG-TT.

METHODS

This cross-sectional study was conducted at the University of Puerto Rico, School of Dental Medicine, Medical Sciences Campus. The participants (18-35 years old) were dental students or employees of the university. Previously, the examiner had been trained and calibrated in instrument usage. Calibration participants (n = 16) received an oral exam, prophylaxis, and a chlorhexidine mouthwash for home use. After 3 days, the upper-anterior teeth were measured using the 2 instruments. The agreement was determined using weighted kappa statistics (Kw), and 0.80 was the minimum acceptable level. The examiner achieved almost perfect agreement (inter-examiner KwT-TC = 0.95 [0.96-0.93]; KwPG-TT = 0.82 [0.81-0.87]) with a reference examiner.

RESULTS

Fifty participants (25 women and 25 men) were evaluated. Length: The teeth of the men presented an unacceptable level of agreement, except for in the right central incisors. For the women, a strong level of agreement was observed only in the lateral incisors and left canines. When the teeth of both sexes were considered, a strong level of agreement was detected, except for in the right canines and left central incisors. Width: The level of agreement was unacceptable, except for in the right canines (distal).

CONCLUSION

T-TC is a more reliable instrument to measure tooth dimensions as compared to the PG-TT.

摘要

目的

比较使用 Chu 比例规(PG-TT)和 Two-Tip Compass(T-TC)测量波多黎各人群上颌前牙牙量的结果,以确定 PG-TT 的可靠性。

方法

这是一项在波多黎各大学牙医学院医学科学校区进行的横断面研究。参与者(18-35 岁)为牙科学员或大学员工。此前,检查者已经接受了关于器械使用的培训和校准。校准参与者(n=16)接受了口腔检查、洁牙和含氯己定的漱口水用于家庭使用。3 天后,使用 2 种器械测量上前牙。使用加权 kappa 统计量(Kw)确定一致性,0.80 是可接受的最低水平。检查者与参考检查者之间达成了几乎完美的一致性(T-TC 检查者 Kw=0.95[0.96-0.93];PG-TT 检查者 Kw=0.82[0.81-0.87])。

结果

共评估了 50 名参与者(25 名女性和 25 名男性)。长度:男性牙齿的一致性除了右侧中切牙外,其余均为不可接受水平。对于女性,只有侧切牙和左侧尖牙显示出很强的一致性。当考虑到男女的牙齿时,除了右侧尖牙和左侧中切牙外,其他牙齿都显示出很强的一致性。宽度:除了右侧尖牙(远中)外,一致性不可接受。

结论

与 PG-TT 相比,T-TC 是一种更可靠的测量牙体尺寸的器械。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验