Suppr超能文献

创伤性肾动脉夹层覆膜支架置入术中的三轴系统:一例报告。

Triaxial system in stent-graft placement for traumatic renal artery dissection: A case report.

作者信息

Okabe Haruka, Suzuki Kazushi, Tsukahara Satoshi, Kagaya Risa, Kitase Masanori, Mizutani Masaru, Shimohira Masashi, Shibamoto Yuta

机构信息

Department of Radiology, Kariya Toyota General Hospital, Kariya 448-8505, Japan.

Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya 467-8601, Japan.

出版信息

Radiol Case Rep. 2020 Dec 18;16(3):493-496. doi: 10.1016/j.radcr.2020.12.032. eCollection 2021 Mar.

Abstract

Stent-graft placement is an important treatment for traumatic renal artery dissection, but it may occasionally be technically difficult to advance a catheter through the lesion of the dissection due to severe stenosis of the true rumen. A triple-coaxial (triaxial) system, which consists of a small microcatheter, a large microcatheter, and a 4-Fr. catheter, has recently become available, and it contributes to super-selective catheterization. We thought this system may be useful for passing catheters through the dissection. We herein report a 30-year-old male patient with traumatic renal artery dissection, who was successfully treated by stent-graft placement using the triaxial system.

摘要

覆膜支架置入术是创伤性肾动脉夹层的重要治疗方法,但由于真腔严重狭窄,有时将导管穿过夹层病变在技术上可能具有挑战性。一种由小型微导管、大型微导管和4F导管组成的三同轴系统最近已投入使用,它有助于超选择性插管。我们认为该系统可能有助于导管穿过夹层。在此,我们报告一名30岁创伤性肾动脉夹层男性患者,他通过使用三同轴系统成功置入覆膜支架进行了治疗。