Okada R D, Glover D, Gaffney T, Williams S
St. Francis Medical Research Institute, Tulsa, OK 74136.
Circulation. 1988 Feb;77(2):491-8. doi: 10.1161/01.cir.77.2.491.
To study the potential usefulness of technetium-99m hexakis-2-methoxy-2-methylpropyl-isonitrile (Tc-MIBI) as a cardiac perfusion imaging agent, the left circumflex coronary arteries of 12 dogs were partially occluded. Eight additional control dogs had no coronary artery stenosis. Myocardial Tc-MIBI activities in the left circumflex and left anterior descending zones were continuously monitored by miniature implantable radiation detectors for 4 hr after administration of the isotope. The dogs were then killed. Serial gamma camera images were also acquired during the study. Heart rate, arterial blood pressure, pressure distal to the stenosis, and cardiac output did not change significantly during the experiment. Microsphere-determined regional myocardial blood flow was significantly reduced in the left circumflex distribution in the 12 dogs with coronary artery stenoses. In the 12 dogs with left circumflex coronary artery stenoses, the 4 hr fractional Tc-MIBI clearances from the normal and ischemic zones were minimal and equivalent (0.15 +/- 0.05 vs 0.15 +/- 0.07). In the eight control dogs, 4 hr fractional Tc-MIBI clearances from the left anterior descending and left circumflex artery zones were minimal and equivalent (0.11 +/- 0.06 vs 0.10 +/- 0.07). Four hour fractional Tc-MIBI clearance from the blood was 0.98 +/- 0.03 for the dogs with stenosis and 0.97 +/- 0.02 for the dogs without stenosis. One additional dog had complete occlusion of the left circumflex coronary artery followed by administration of Tc-MIBI and scandium-46-labeled microspheres. This heart was immediately sectioned and counted to determine the relationship of regional blood flow to Tc-MIBI distribution (r = .92).(ABSTRACT TRUNCATED AT 250 WORDS)
为研究锝-99m六甲基异丁基异腈(Tc-MIBI)作为心脏灌注显像剂的潜在效用,对12只犬的左旋冠状动脉进行部分闭塞。另外8只对照犬无冠状动脉狭窄。在给予同位素后,通过微型植入式辐射探测器连续4小时监测左旋和左前降支区域的心肌Tc-MIBI活性。然后将犬处死。研究期间还采集了系列γ相机图像。实验过程中心率、动脉血压、狭窄远端压力和心输出量无显著变化。在12只患有冠状动脉狭窄的犬中,微球测定的左旋支分布区域的局部心肌血流显著减少。在12只患有左旋冠状动脉狭窄的犬中,正常和缺血区域4小时的Tc-MIBI清除分数极小且相等(0.15±0.05对0.15±0.07)。在8只对照犬中,左前降支和左旋支动脉区域4小时的Tc-MIBI清除分数极小且相等(0.11±0.06对0.10±0.07)。狭窄犬的血液4小时Tc-MIBI清除分数为0.98±0.03,无狭窄犬为0.97±0.02。另一只犬左旋冠状动脉完全闭塞,随后给予Tc-MIBI和钪-46标记的微球。立即将该心脏切片并计数,以确定局部血流与Tc-MIBI分布的关系(r = 0.92)。(摘要截短于250字)