Dupont M C, Hochman H I
Department of Surgery, University of Wisconsin Hospital and Clinics, Madison.
J Urol. 1988 Feb;139(2):367-8. doi: 10.1016/s0022-5347(17)42418-9.
We report a case of erosion of an inflatable penile prosthesis reservoir int the bladder 4 years after implantation for organic impotence. In contrast to previously reported cases this complication was not associated with incontinence, urinary tract infection or a revision procedure. Microscopic hematuria was present but there was no pyuria. Diagnosis evaded radiographic and cystoscopic confirmation. Bladder erosion of the reservoir was discovered incidentally during treatment of bladder calculi.
我们报告一例因器质性阳痿植入可膨胀阴茎假体储液囊4年后,该储液囊侵蚀入膀胱的病例。与先前报道的病例不同,该并发症与尿失禁、尿路感染或翻修手术无关。存在镜下血尿,但无脓尿。影像学和膀胱镜检查均未能确诊。储液囊膀胱侵蚀是在膀胱结石治疗过程中偶然发现的。