Zhao W, Song S, Yan H F
National Institute of Occupational Health and Poison Control, Chinese Center for Disease Control and Prevention, Beijing 100050, China.
Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi. 2020 Dec 20;38(12):937-940. doi: 10.3760/cma.j.cn121094-20191126-00545.
To establish an ultra-high performance liquid chromatography method for the determination of mifepristone in the air of workplaces. From January to July 2018, glass fiber filter membrane was used to collect mifepristone in the workplace air, eluted with acetonitrile/water solution, and determined by ultra-high performance liquid chromatography-UV method. The detection limit of mifepristone determination method was 0.005 μg/ml, the lower limit of quantification was 0.015 μg/ml, and the lowest detection concentration was 0.14 μg/m(3) (calculated by collecting 75 L air samples) . The concentration of mifepristone has a good linear relationship between 0.015-40.24 μg/ml, =0.9999. The accuracy and elution efficiency of the method were calculated based on the recovery rate, ranging from 92.7% to 100.0%. The average sampling efficiency was 99.6%-100.0%. The intra-assay precision of the method was 0.92% to 5.41%, and the inter-assay precision was 0.89% to 6.25%. The sample could be stored stably for 3 days at 4°C. The ultra-high performance liquid chromatography method for determination of mifepristone is easy to operate, and its indicators meet the requirements of GBZ/T 201.4-2008 "Guidelines for the Establishment of Occupational Hygiene Standards Part 4: Methods for Determination of Chemical Substances in Workplace Air", which is suitable for the detection of mifepristone in the air of the workplace.