Suppr超能文献

循环纤维蛋白原在诊断假体相关性感染中的可靠性:系统评价和荟萃分析。

Reliability of circulating fibrinogen in the diagnosis of prosthesis-related infections: a systematic review and meta-analysis.

机构信息

The First Clinical Medical School, Guangzhou University of Chinese Medicine, Jichang Road 12#, District Baiyun, Guangzhou, Guangdong, China.

Yichuan People's Hospital, Jiuchang Road 21#, District Yichuan, Luoyang, Henan, China.

出版信息

J Orthop Surg Res. 2021 Jan 9;16(1):31. doi: 10.1186/s13018-020-02171-x.

Abstract

BACKGROUND

Fibrinogen (FIB) has recently been used as a biomarker to diagnose periprosthetic joint infection (PJI), but its reliability is still questionable. The aim of this study was to investigate the accuracy of FIB in the diagnosis of PJI after joint replacement.

METHODS

We searched for literatures published in PubMed, EMBASE, and the Cochrane Library from the time of database inception to September 2020 and screened the studies according to the inclusion criteria. Then, we calculated the diagnostic parameters of FIB, including the pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), area under the curve (AUC), and diagnostic odds ratio (DOR). In addition, we implemented subgroup analyses to identify the sources of heterogeneity.

RESULTS

Seven studies including 1341 patients were selected in our meta-analysis. The pooled sensitivity, specificity, PLR, NLR, and DOR of FIB for PJI diagnosis were 0.78 (95% confidence interval [CI], 0.73-0.82), 0.83 (95% CI, 0.81-0.86), 4.60 (95% CI, 3.30-6.42), 0.24 (95% CI, 0.18-0.34), and 20.13 (95% CI, 14.80-27.36), respectively, while the AUC was 0.896.

CONCLUSION

The present study indicated that FIB was a reliable detection method and might be introduced into the diagnostic criteria for PJI. However, more robust studies are still needed to confirm the current findings, because most of the included studies were retrospective and had small sample sizes.

摘要

背景

纤维蛋白原(FIB)最近被用作诊断人工关节置换术后假体周围关节感染(PJI)的生物标志物,但它的可靠性仍存在疑问。本研究旨在探讨 FIB 在诊断人工关节置换术后 PJI 中的准确性。

方法

我们检索了 PubMed、EMBASE 和 Cochrane 图书馆自数据库建立以来至 2020 年 9 月发表的文献,并根据纳入标准筛选研究。然后,我们计算了 FIB 的诊断参数,包括合并敏感性、特异性、阳性似然比(PLR)、阴性似然比(NLR)、曲线下面积(AUC)和诊断比值比(DOR)。此外,我们还进行了亚组分析以确定异质性的来源。

结果

我们的荟萃分析共纳入了 7 项研究,包括 1341 例患者。FIB 对 PJI 诊断的合并敏感性、特异性、PLR、NLR 和 DOR 分别为 0.78(95%置信区间[CI],0.73-0.82)、0.83(95% CI,0.81-0.86)、4.60(95% CI,3.30-6.42)、0.24(95% CI,0.18-0.34)和 20.13(95% CI,14.80-27.36),AUC 为 0.896。

结论

本研究表明 FIB 是一种可靠的检测方法,可能被引入 PJI 的诊断标准。然而,由于大多数纳入的研究是回顾性的,且样本量较小,仍需要更多的研究来证实当前的发现。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c5b8/7797116/1f7934e5c39b/13018_2020_2171_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验