Suppr超能文献

[Feasibility of single-stage stent implantation following rotational atherectomy combined with TAVR].

作者信息

Wang M Y, Song G Y, Niu G N, Ye Y Q, Wang Y B, Luo T, Teng S Y, Wu Y J

机构信息

Structure Heart Disease Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China.

出版信息

Zhonghua Xin Xue Guan Bing Za Zhi. 2021 Jan 11;49(1):66-70. doi: 10.3760/cma.j.cn112148-20200226-00129.

Abstract

To explore the feasibility of the single-stage stent implantation following rotational atherectomy combined with transcatheter aortic valve replacement (TAVR) in treating patients with severe aortic stenosis(AS) and severe calcified coronary artery stenosis. Three patients who received single-stage stent implantation following rotational atherectomy combined with TAVR in Fuwai hospital from April to October 2019 were included in this retrospective analysis. Clinical and anatomical features (including echocardiography and aortic CT) of the patients were collected, efficacy and safety of this operation strategy were observed and 6 months follow up results were summarized. Three patients (2 females, 66-80 years old) were included. The mean Society of Thoracic Surgeons (STS) risk score was 7.8%. The mean maximum velocity of aortic valve was 4.4 m/s, the mean transvalvular pressure gradient was 53.2 mmHg (1 mmHg=0.133 kPa), mean left ventricular ejection fraction (LVEF) was 48.6%. All three patients had severe calcified coronary artery stenosis: left anterior descending artery (LAD, =2) and left main coronary artery (LM, =1), requiring rotary grinding. The mean SYNTAX score was 20. All the procedures were performed through transfemoral access. After aortic valve crossing, all coronary lesions were successfully treated with stent implantation following rotational atherectomy, transfemoral TAVR was then immediately performed with a self-expandable Venus-A valve. One patient underwent"valve-in-valve"implantation due to the high-implantation position of the first valve. The procedures were completed without complications in all the three patients. The immediate effect was satisfactory. Echocardiography results showed that the mean maximum velocity of aortic valve was 2.1 m/s, mean gradient was 9.3 mmHg, and mean LVEF was 59% after the procedure. There was no death and revascularization during the 6 months follow-up. In patients with severe calcified coronary artery and severe AS with high risk of cardiac surgery, the single-stage stent implantation following rotational atherectomy combined with TAVR is feasible and results are satisfactory in this patient cohort.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验