Suppr超能文献

两种不同设计的种植体在极软骨质中适合即刻负重的初期稳定性值的体外评估

An In Vitro Evaluation of Primary Stability Values for Two Differently Designed Implants to Suit Immediate Loading in Very Soft Bone.

作者信息

Krischik Dirk, Tokgöz Selen Ergin, van Orten Andreas, Friedmann Anton, Bilhan Hakan

机构信息

Private Dental Practice Zahnärzte Do24, Dortmunder Str. 24-28, 45731 Waltrop, Germany.

Private Dental Practice, Dentaglobal Oral Health Centre, Adalet Str 2131/10 No:3A, 35530 Bayraklı/İzmir, Turkey.

出版信息

Dent J (Basel). 2021 Jan 8;9(1):5. doi: 10.3390/dj9010005.

Abstract

The achievement of sufficient implant stability in poor quality bone seems to be a challenge. Most manufacturers develop special dental implants, which are claimed to show higher stability even in very soft bone. The aim of this experimental study was to compare two recently introduced dental implants with differing thread designs. A total of 11 implants of each group were inserted in the part of the fresh bovine ribs, corresponding to very soft bone. The primary stability was measured with resonance frequency analysis (RFA) and Periotest; the average of two measurements for each method and for each implant was taken and statistical analysis was applied. The highest stability values were obtained with the ICX Active Master implants, followed by the Conelog Progressive-Line implants placed with the very soft bone protocol. The primary stability values of the Conelog Progressive-Line implants inserted by the very soft bone protocol and the ICX Active Master implants placed with the standard protocol showed sufficient stability for immediate loading in low-density bone. Within the limitations of this study, the thread design of the implants and underdimensioned implant bed preparation seem to be effective for better primary stability in cancellous bone.

摘要

在质量较差的骨组织中实现足够的种植体稳定性似乎是一项挑战。大多数制造商开发了特殊的牙科种植体,据称这些种植体即使在非常松软的骨组织中也能表现出更高的稳定性。本实验研究的目的是比较两种最近推出的具有不同螺纹设计的牙科种植体。每组共11枚种植体被植入新鲜牛肋骨中相当于非常松软骨组织的部位。使用共振频率分析(RFA)和牙周探针测量初始稳定性;记录每种方法和每个种植体两次测量的平均值并进行统计分析。ICX Active Master种植体获得了最高的稳定性值,其次是按照非常松软骨组织植入方案植入的Conelog Progressive-Line种植体。按照非常松软骨组织植入方案植入的Conelog Progressive-Line种植体以及按照标准植入方案植入的ICX Active Master种植体的初始稳定性值表明,在低密度骨中即刻负重具有足够的稳定性。在本研究的局限性范围内,种植体的螺纹设计和种植窝预备不足似乎对提高松质骨中的初始稳定性有效。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f649/7827002/ffea68feed9b/dentistry-09-00005-g001.jpg

相似文献

2
The effect of osseodensification and different thread designs on the dental implant primary stability.
F1000Res. 2018 Dec 5;7:1898. doi: 10.12688/f1000research.17292.1. eCollection 2018.
3
In vitro comparison of primary stability of two implant designs in D3 bone.
Med Oral Patol Oral Cir Bucal. 2017 Jul 1;22(4):e473-e477. doi: 10.4317/medoral.21714.
7
Required minimum primary stability and torque values for immediate loading of mini dental implants: an experimental study in nonviable bovine femoral bone.
Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2008 Feb;105(2):e20-7. doi: 10.1016/j.tripleo.2007.10.003.

引用本文的文献

1
The Influence of Implant Macro-geometry in Primary Stability in Low-Density Bone: An Study.
J Int Soc Prev Community Dent. 2025 Apr 30;15(2):134-143. doi: 10.4103/jispcd.jispcd_155_24. eCollection 2025 Mar-Apr.
3
Randomized Clinical Trial: Bone Bioactive Liquid Improves Implant Stability and Osseointegration.
J Funct Biomater. 2024 Oct 1;15(10):293. doi: 10.3390/jfb15100293.

本文引用的文献

2
4
Effect of bone quality, implant design, and surgical technique on primary implant stability.
Quintessence Int. 2018 Jan 22:189-198. doi: 10.3290/j.qi.a39745.
6
Comparison of the Primary Stability of Two Implant Designs in Two Different Bone Types: An In Vitro Study.
Int J Oral Maxillofac Implants. 2015 Sep-Oct;30(5):1036-40. doi: 10.11607/jomi.3939.
7
Influence of underpreparation on primary stability of implants inserted in poor quality bone sites: an in vitro study.
J Oral Maxillofac Surg. 2015 Jun;73(6):1084-8. doi: 10.1016/j.joms.2015.01.029. Epub 2015 Feb 7.
9
Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation.
Interv Med Appl Sci. 2013 Dec;5(4):162-7. doi: 10.1556/IMAS.5.2013.4.3. Epub 2013 Dec 20.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验