PET-CT Center, the First People's Hospital of Yunnan Province, Kunming, 650032, Yunnan Province, China.
Department of Radiation, the First People's Hospital of Yunnan Province, Kunming, 650032, Yunnan Province, China.
Sci Rep. 2021 Jan 15;11(1):1546. doi: 10.1038/s41598-021-81358-6.
This study aimed to develop and validate a novel rabbit fixator made from a thermoplastic mask for awake imaging experiments. When heated in a hot-water bath at 65-70 °C for 2-5 min, the thermoplastic mask became soft and could be molded to fit over the entire body of an anesthetized rabbit (4 ml of 3% pentobarbital sodium solution by intramuscular injection). Twenty rabbits were randomly divided into fixator (n = 10) and anesthesia (n = 10) groups. The animals' vital signs, stress hormones (cortisol and adrenaline), and subjective image quality scores for the computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI) scanning were measured and compared. Phantom CT, MRI and PET studies were performed to assess the performance with and without the thermoplastic mask by using image agents at different concentrations or with different radioactivity. The respiration rate (RR), systolic blood pressure (SBP), diastolic blood pressure (DBP), peripheral capillary oxygen saturation (SpO) and body temperature (T) decreased after anesthesia (all P < 0.05) but did not significantly decrease after fixation (all P > 0.05). The heart rate (HR), cortisol and adrenaline did not significantly decrease after either anesthesia or fixation (all P > 0.05). The subjective image quality scores for the CT and MRI images of the head, thorax, liver, kidney, intestines and pelvis and the subjective image quality scores for the PET images did not significantly differ between the two groups (all P > 0.05). For all examined organs except the muscle, F-FDG metabolism was lower after fixation than after anesthesia, and was almost identical of liver between two groups. The phantom study showed that the CT values, standard uptake values and MR T2 signal values did not differ significantly with or without the mask (all P > 0.05). A novel rabbit fixator created using a thermoplastic mask could be used to obtain high-quality images for different imaging modalities in an awake and near-physiological state.
本研究旨在开发和验证一种新颖的兔用固定器,该固定器由热塑面具制成,可用于清醒状态下的成像实验。将热塑面具在 65-70°C 的热水浴中加热 2-5 分钟,面具变软后可塑形以贴合麻醉兔的整个身体(通过肌肉注射 4 毫升 3%戊巴比妥钠溶液)。20 只兔子被随机分为固定器(n=10)和麻醉(n=10)两组。测量并比较了动物的生命体征、应激激素(皮质醇和肾上腺素)以及 CT、正电子发射断层扫描(PET)和磁共振成像(MRI)扫描的主观图像质量评分。进行了体模 CT、MRI 和 PET 研究,以评估使用不同浓度的成像剂或不同放射性活度时使用和不使用热塑面具的性能。呼吸频率(RR)、收缩压(SBP)、舒张压(DBP)、外周毛细血管血氧饱和度(SpO2)和体温(T)在麻醉后下降(均 P<0.05),但固定后无明显下降(均 P>0.05)。麻醉或固定后,心率(HR)、皮质醇和肾上腺素均无明显下降(均 P>0.05)。头部、胸部、肝脏、肾脏、肠道和骨盆的 CT 和 MRI 图像以及 PET 图像的主观图像质量评分在两组之间无显著差异(均 P>0.05)。除肌肉外,所有检查器官的 F-FDG 代谢在固定后均低于麻醉后,且两组之间肝脏的代谢几乎相同。体模研究表明,有无面具时 CT 值、标准摄取值和 MR T2 信号值无明显差异(均 P>0.05)。使用热塑面具制作的新型兔用固定器可用于在清醒且接近生理状态下获得不同成像方式的高质量图像。