Bidirectional transvenous/subcutaneous defibrillation of ventricular fibrillation in dogs: success rates, energy requirements, currents, voltages and impedance.

作者信息

Budde T, Vukmirovic N B, Soriano-Romero J M, Abu-Ghazaleh S, Borggrefe M, Schmiel F K, Pölitz B, Arnold G, Breithardt G

机构信息

Medical Hospital, Düsseldorf, Department of Cardiology, Pneumology and Angiology, F.R.G.

出版信息

Eur Heart J. 1988 Jan;9(1):92-101.

PMID:3345775
Abstract

Four hundred and thirteen defibrillations of alternating current-induced ventricular fibrillation were performed in 10 halothane-anaesthetized dogs (body weight: 24.5-30.5 kg). Success rates, energy demands, currents, peak voltages and impedance were determined. A transvenous catheter electrode system (Medtronic 6880, right ventricular apex and superior vena cava, distance 100 or 150 mm) and subcutaneous patch electrodes (Intec 67 L, 2nd/3rd and/or 3rd/4th left intercostal space) were used for bidirectional defibrillation. Loading voltages ranged from 600 to 850 V. With an electrode distance of 100 mm and a pulse duration of 2 ms separated by 1 ms, success rates were 100%, 40% and 0% for 850.650 and 600 V, respectively. With a 3-ms pulse duration, the corresponding rates were 100%, 60% and 50%. With a 2-ms pulse duration, successful defibrillation was achieved with energies lower than 15 J in 27%, with energies between 15 and 20 J in 77%, and 100% with energies higher than 20 J. Defibrillation currents were 4.4-9.3 A for pulse 1 (superior vena cava/ventricular apex) and 6.3-13.4 A for pulse 2 (patch/ventricular apex), respectively. Effective peak voltages ranged from 510 to 787 V and from 514 to 777V and averaged 89.6% of the loading voltages. Impedance values (peak voltage/current) were 75.5-117.7 (pulse 1) and 51.7-94.9 Ohms (pulse 2). Fifty consecutive defibrillations in one animal resulted in a decrease of impedance (114.6 to 84.9 Ohms, pulse 1:75.4 to 53.0 Ohms, pulse 2). Defibrillation of ventricular fibrillation can be achieved with acceptably low energies using a bidirectional transvenous/subcutaneous system, avoiding thoracotomy and general anaesthesia for implantation of the defibrillation system.

摘要

相似文献

1
Bidirectional transvenous/subcutaneous defibrillation of ventricular fibrillation in dogs: success rates, energy requirements, currents, voltages and impedance.
Eur Heart J. 1988 Jan;9(1):92-101.
2
Direct comparison of monophasic, biphasic and sequential pulse defibrillation over a single current pathway.在单一电流路径上对单相、双相和序贯脉冲除颤进行直接比较。
Can J Cardiol. 1996 Apr;12(4):407-11.
3
Optimization of epicardial electrode size and implant site for reduced sequential pulse defibrillation thresholds.
Med Instrum. 1986 Jan-Feb;20(1):36-9.
4
Comparison of defibrillation probability of success curves for an endocardial lead configuration with and without an inactive epicardial patch.具有和不具有非活性心外膜贴片的心内膜导联配置的除颤成功概率曲线比较。
J Am Coll Cardiol. 1995 May;25(6):1373-9. doi: 10.1016/0735-1097(94)00558-8.
5
[Nonthoracotomy internal defibrillation in dogs using a body surface electrode with a transvenous catheter electrode].
Hokkaido Igaku Zasshi. 1989 Jul;64(4):450-6.
6
The importance of the electrode system for the success of intracardiac defibrillation.电极系统对心内除颤成功的重要性。
Cor Vasa. 1988;30(6):405-12.
7
Sequential pulse defibrillation for implantable defibrillators.
Med Instrum. 1986 May-Jun;20(3):138-42.
8
Effect of rapid biphasic shock subpulse switching on ventricular defibrillation thresholds.快速双相电击子脉冲切换对心室除颤阈值的影响。
J Cardiovasc Electrophysiol. 2004 Jul;15(7):802-8. doi: 10.1046/j.1540-8167.2004.03652.x.
9
Influence of ventricular fibrillation duration on defibrillation energy in dogs using bidirectional pulse discharges.双向脉冲放电时心室颤动持续时间对犬除颤能量的影响
Pacing Clin Electrophysiol. 1988 Sep;11(9):1315-23. doi: 10.1111/j.1540-8159.1988.tb03994.x.
10
Importance of electrode design, lead configuration and impedance for successful low energy transcatheter atrial defibrillation in dogs.电极设计、导联配置和阻抗对犬成功进行低能量经导管心房除颤的重要性。
J Am Coll Cardiol. 1993 Oct;22(4):1199-206. doi: 10.1016/0735-1097(93)90438-7.

引用本文的文献

1
Role of peak current in conversion of patients with ventricular fibrillation.峰值电流在心室颤动患者转复中的作用。
Singapore Med J. 2017 Jul;58(7):432-437. doi: 10.11622/smedj.2017070.