Mahmud F A, Hastings G W, Martini M
Institut National d'Eléctricité et d'Eléctronique, Boumerdes, Algeria.
J Biomed Eng. 1988 Jan;10(1):54-6. doi: 10.1016/0141-5425(88)90026-x.
A model has been developed to characterize the strain generated potentials (SGPs) in bone. The model relates the SGP signal to the rotation (reorientation) of the spontaneous dipoles of bone in response to mechanical deformation. The effects of bone structural conditions and the measuring circuitry on the recorded potential are both accounted for by the model.
已经开发出一种模型来表征骨骼中应变产生的电位(SGP)。该模型将SGP信号与骨骼自发偶极子响应机械变形的旋转(重新定向)联系起来。该模型考虑了骨骼结构条件和测量电路对记录电位的影响。