Suppr超能文献

数字断层融合摄影术在舟状骨骨折管理中的诊断性能和高级成像减少。

Diagnostic Performance and Advanced Imaging Reduction With Digital Tomosynthesis in Scaphoid Fracture Management.

机构信息

Albany Medical Center, NY, USA.

University of California, Berkley, USA.

出版信息

Hand (N Y). 2022 Nov;17(6):1128-1132. doi: 10.1177/1558944720988120. Epub 2021 Jan 24.

Abstract

BACKGROUND

Management of scaphoid fractures often requires advanced imaging to achieve accurate diagnoses and appropriate treatment. Digital tomosynthesis (DTS) is a cross-sectional imaging modality that may be used to substitute magnetic resonance imaging or computed tomographic scans. The purpose of this study is to: (1) determine the diagnostic accuracy of DTS in occult scaphoid fractures; and (2) report on the reduction of other advanced imaging when using DTS.

METHODS

From May 2014 to October 2017, the charts of all patients who underwent scaphoid tomogram were retrospectively reviewed. The diagnostic accuracy of DTS for occult fracture was compared with 2-week follow-up plain films. To measure the reduction in utilization of advanced imaging, it was determined whether DTS eliminated the need for advanced imaging by providing adequate information regarding the clinical question.

RESULTS

A total of 78 patients underwent scaphoid tomography in this time frame: 39 for occult fracture, 33 for fracture union, 5 for fracture morphology, and 1 for hardware positioning. For the detection of occult fracture, DTS had a sensitivity of 100%, specificity of 83%, positive predictive value of 64%, and negative predictive value of 100%. Advanced imaging was not used in 35 of the remaining 39 patients based on the results obtained by DTS. In patients who did receive advanced imaging, 83% of tomograms provided conclusive diagnostic information.

CONCLUSIONS

Digital tomosynthesis increases the diagnostic sensitivity of occult scaphoid fractures, reducing unnecessary immobilization and advanced imaging. Digital tomosynthesis provides clinical detail beyond plain film, which reduces the need to obtain advanced imaging when assessing union, fracture pattern, and hardware placement.

摘要

背景

对舟状骨骨折的治疗通常需要先进的影像学检查以实现准确诊断和适当治疗。数字断层合成术(DTS)是一种可以替代磁共振成像或计算机断层扫描的横截面成像方式。本研究的目的是:(1)确定 DTS 对隐匿性舟状骨骨折的诊断准确性;(2)报告使用 DTS 减少其他先进影像学检查的情况。

方法

从 2014 年 5 月至 2017 年 10 月,对所有接受舟状骨断层扫描的患者的病历进行了回顾性分析。DTS 对隐匿性骨折的诊断准确性与 2 周后的常规 X 线片进行了比较。为了衡量减少使用先进影像学检查的程度,通过确定 DTS 是否为解决临床问题提供了充分的信息,从而消除了对高级影像学检查的需求。

结果

在此期间共有 78 例患者接受了舟状骨断层扫描:39 例用于隐匿性骨折,33 例用于骨折愈合,5 例用于骨折形态,1 例用于硬件定位。对于隐匿性骨折的检测,DTS 的灵敏度为 100%,特异性为 83%,阳性预测值为 64%,阴性预测值为 100%。根据 DTS 结果,其余 39 例患者中有 35 例未进行高级影像学检查。在接受高级影像学检查的患者中,83%的断层扫描提供了明确的诊断信息。

结论

数字断层合成术提高了隐匿性舟状骨骨折的诊断灵敏度,减少了不必要的固定和高级影像学检查。数字断层合成术提供了超出常规 X 线片的临床细节,减少了在评估愈合、骨折形态和硬件位置时获得高级影像学检查的需求。

相似文献

1
Diagnostic Performance and Advanced Imaging Reduction With Digital Tomosynthesis in Scaphoid Fracture Management.
Hand (N Y). 2022 Nov;17(6):1128-1132. doi: 10.1177/1558944720988120. Epub 2021 Jan 24.
2
Can a Deep Learning Algorithm Improve Detection of Occult Scaphoid Fractures in Plain Radiographs? A Clinical Validation Study.
Clin Orthop Relat Res. 2023 Sep 1;481(9):1828-1835. doi: 10.1097/CORR.0000000000002612. Epub 2023 Mar 7.
3
Clinical utility of tomosynthesis in suspected scaphoid fracture. A pilot study.
Skeletal Radiol. 2011 Jul;40(7):863-7. doi: 10.1007/s00256-010-1049-3. Epub 2010 Nov 6.
4
The use of digital tomosynthesis in suspected scaphoid fractures.
J Hand Surg Eur Vol. 2024 May;49(5):630-631. doi: 10.1177/17531934231215769. Epub 2023 Nov 24.
5
Tomosynthesis: A new radiologic technique for rapid diagnosis of scaphoid fractures.
Surgeon. 2018 Jun;16(3):131-136. doi: 10.1016/j.surge.2016.10.004. Epub 2016 Dec 21.
6
Management and Outcomes of Clinical Scaphoid Fractures in Children.
Hand (N Y). 2022 May;17(3):459-464. doi: 10.1177/1558944720930293. Epub 2020 Jul 1.
7
Digital Tomography for Detection of Acute Occult Scaphoid Fractures.
Orthopedics. 2017 Nov 1;40(6):e1092-e1095. doi: 10.3928/01477447-20171020-05.
8
Diagnostic value of cone beam computed tomography (CBCT) in occult scaphoid and wrist fractures.
Eur J Radiol. 2017 Dec;97:59-64. doi: 10.1016/j.ejrad.2017.10.010. Epub 2017 Oct 18.
9
Prospective comparison of magnetic resonance imaging and computed tomography in diagnosing occult scaphoid fractures.
Acta Radiol. 2023 Jan;64(1):201-207. doi: 10.1177/02841851211064595. Epub 2021 Dec 17.
10
Adult scaphoid fracture.
Acad Emerg Med. 2014 Feb;21(2):101-21. doi: 10.1111/acem.12317.

引用本文的文献

1
Diagnostic performance of digital tomosynthesis for postoperative assessment of acetabular fractures and pelvic ring injuries.
Front Surg. 2024 Oct 25;11:1461144. doi: 10.3389/fsurg.2024.1461144. eCollection 2024.

本文引用的文献

1
Digital Tomography for Detection of Acute Occult Scaphoid Fractures.
Orthopedics. 2017 Nov 1;40(6):e1092-e1095. doi: 10.3928/01477447-20171020-05.
2
Postoperative imaging of orthopaedic hardware in the hand and wrist: is there an added value for tomosynthesis?
Clin Radiol. 2018 Feb;73(2):214.e1-214.e9. doi: 10.1016/j.crad.2017.08.001. Epub 2017 Sep 11.
3
Whole-Body Clinical Applications of Digital Tomosynthesis.
Radiographics. 2016 May-Jun;36(3):735-50. doi: 10.1148/rg.2016150184.
5
Diagnosis of Occult Scaphoid Fractures: A Cost-Effectiveness Analysis.
J Bone Joint Surg Am. 2015 Nov 18;97(22):1860-8. doi: 10.2106/JBJS.O.00099.
6
Ewing Sarcoma: Current Management and Future Approaches Through Collaboration.
J Clin Oncol. 2015 Sep 20;33(27):3036-46. doi: 10.1200/JCO.2014.59.5256. Epub 2015 Aug 24.
9
Cost and clinical effectiveness of MRI in occult scaphoid fractures: a randomised controlled trial.
Emerg Med J. 2013 Mar;30(3):202-7. doi: 10.1136/emermed-2011-200676. Epub 2012 Apr 13.
10
'Clinical scaphoid fracture': is it time to abolish this phrase?
Ann R Coll Surg Engl. 2011 Mar;93(2):146-8. doi: 10.1308/147870811X560886.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验