Suppr超能文献

超微剂量 CT 在急诊科腕部外伤中的应用

Ultra-low-dose computed tomography and its utility in wrist trauma in the emergency department.

机构信息

Department of Emergency Medicine, Ataturk University Faculty of Medicine, Erzurum, Turkey.

Department of Orthopedics and Traumatology, Ataturk University Faculty of Medicine, Erzurum, Turkey.

出版信息

Acta Radiol. 2022 Feb;63(2):192-199. doi: 10.1177/0284185121989958. Epub 2021 Jan 28.

Abstract

BACKGROUND

The use and frequency of computed tomography (CT) are increasing day by day in emergency departments (ED). This increases the amount of radiation exposed.

PURPOSE

To evaluate the image quality obtained by ultra-low-dose CT (ULDCT) in patients with suspected wrist fractures in the ED and to investigate whether it is an alternative to standard-dose CT (SDCT).

MATERIAL AND METHODS

This is a study prospectively examining 336 patients who consulted the ED for wrist trauma. After exclusion criteria were applied, the patients were divided into the study and control groups. Then, SDCT (120 kVp and 100 mAs) and ULDCT (80 kVp and 5 mAs) wrist protocols were applied simultaneously. The images obtained were evaluated for image quality and fracture independently by a radiologist and an emergency medical specialist using a 5-point scale.

RESULTS

The effective radiation dose calculated for the control group scans was 41.1 ± 2.1 µSv, whereas the effective radiation dose calculated for the study group scans was 0.5 ± 0.0 µSv. The effective radiation dose of the study group was significantly lower than that of the control group ( < 0.01). The CT images in the study group showed no significant differences in the mean image quality score between observer 1 and observer 2 (3.4 and 4.3, respectively;  = 0.58). Both observers could detect all fractures using the ULDCT images.

CONCLUSION

ULDCT provides high-quality images in wrist traumas while reducing the radiation dose by approximately 98% compared to SDCT without any changes in diagnostic accuracy.

摘要

背景

在急诊科(ED),计算机断层扫描(CT)的使用和频率日益增加。这增加了辐射暴露量。

目的

评估疑似腕部骨折的 ED 患者接受超低剂量 CT(ULDCT)检查获得的图像质量,并研究其是否可替代标准剂量 CT(SDCT)。

材料和方法

这是一项前瞻性研究,共检查了 336 名因腕部创伤就诊于 ED 的患者。应用排除标准后,患者被分为研究组和对照组。然后,同时进行 SDCT(120 kVp 和 100 mAs)和 ULDCT(80 kVp 和 5 mAs)腕关节方案。由放射科医生和急诊医学专家使用 5 分制独立评估图像质量和骨折。

结果

对照组扫描的有效辐射剂量计算值为 41.1 ± 2.1 µSv,而研究组扫描的有效辐射剂量计算值为 0.5 ± 0.0 µSv。研究组的有效辐射剂量明显低于对照组( < 0.01)。研究组的 CT 图像在观察者 1 和观察者 2之间的平均图像质量评分无显著差异(分别为 3.4 和 4.3;  = 0.58)。两位观察者均能使用 ULDCT 图像检测到所有骨折。

结论

与 SDCT 相比,ULDCT 可在不影响诊断准确性的情况下,将腕部创伤的辐射剂量降低约 98%,同时提供高质量的图像。